2. Operation
WARNING
- DO NOT OPERATE THIS EQUIPMENT IF IT HAS A KNOWN FAULT.
Before starting the pump
1.
Make sure the pump is correctly installed in accordance with the installation instruction detailed in
chapter 1.
2.
When a pump is newly installed, check all fastenings are tightened to the correct torque value.
Torque figures are
detailed in chapter 5.2 Table 3
.
Operation of pump
1.
Ensure any valves located in the suction and delivery pipework are open.
2.
Open the air inlet valve and apply air pressure.
3.
If a valve is fitted adjacent to the pump on the delivery side of the fluid pipework, this can be used
to control flow. Alternatively the pump may be controlled by adjusting the air supply.
Noise levels
Noise levels from the Flotronic Pumps pump will generally not exceed 85 decibels at one metre distance.
Hearing protection may be required.
Recommendations for Best Pump Performance
The following points should be observed to achieve the best results from all Flotronic pumps:
1.
Operate the pump at the minimum speed and pressure to achieve the required duty point.
2.
Ensure suction pipework is free from restrictions and as short as possible.
3.
Suction pipework diameter should be at least the same as the pump inlet
4.
Dry running should be kept to a minimum.
5.
Air connection to have a minimum ID of 10mm.