Assembly of the pump
Assembly of the Flotronic Slimline pump can be easily achieved by competent personnel.
Spares required:
As identified during inspection.
Supplies required:
Suitable lubricant (as per site protocol)
To assemble the Flotronic Slimline pump, perform the following procedure:
Fig 21
1. Ensure all component parts are present and
check for wear or damage, replace if
necessary. Clean parts prior to assembly
using appropriate cleaning agents.
Special attention should be paid to the diaphragm
sealing faces on body and thrust tube.
Fig 22
2. Install the two suction manifold ‘O’ rings,
ensuring sufficient care is taken not to
damage the ‘O’ rings.
Pumps fitted with optional replaceable seats will
have 2 ‘O’ rings per seat (Fig 19)
Fig 23
3. Install the two suction balls in the suction
manifolds.
4. Position the main body on the suction
manifold.
www.unibloctech.co