![UNIBLOC FLOTRONIC ONE-NUT Installation, Operation And Maintenance Manual Download Page 34](http://html1.mh-extra.com/html/unibloc/flotronic-one-nut/flotronic-one-nut_installation-operation-and-maintenance-manual_839143034.webp)
Data
34
5. Data
Technical data
Maximum Air Pressure
7.2 Barg
Maximum Delivery Pressure
7.2 Barg
Maximum Suction Pressure
7.2 Barg with optional reinforced
diaphragms fitted.
0.5 Barg with standard diaphragms.
Maximum Media Temperature
135°C (275°F) depending on diaphragm
material
Minimum Media Temperature
-15°C (5°F) depending on diaphragm
material
Suction Lift
Dry
3.6m (12ft)
Wet
8m (26ft)
Average Volume per Stroke
0.90 litres
Tightening torques
Before the pump is put into service and after any maintenance, tighten the fastenings to the torque figures
given in Table 3 ensuring fasteners are suitably lubricated.
TABLE 3 – TORQUE FIGURES
Diaphragm Material
LB/FT
Nm
KGM
Tie Rod Nut:
Stainless Steel /
Mild Steel
PTFE/Nitrile
175
240
24
Tie Rod Nut:
Silver Plated
PTFE/Nitrile
105
140
14
Manifold
Stainless Steel
15
20
2
www.unibloctech.co