Installation
12
1. Installation
Packaging and Shipping
Inspection
Although precaution is taken when packaging and shipping, we urge you to carefully check the shipment on
receipt. Make sure that all parts and accessories listed on the packaging list are accounted for. Immediately
report any damage or shortage to the Transport Company and Flotronic Pumps.
Storage
If the equipment is to be stored prior to installation, place in a clean location. The pump should be stored in
an ambient temperature of 15◦C (59◦F) to 25◦C (77◦F) and relative humidity below 65%. Do not remove the
protective covers from the suction, delivery and air connections which have been fastened to keep pump
internals free of debris.
Installing the Slimline Pump
1.3.1.
Foundation
The pump will operate properly without being fixed to a foundation, however if the pump is required to be
fixed in position, all
Flotronic Pumps
are provided with mounting plates and suitable holes for bolting.
1.
Mount the pump to a suitable base plate or foundation.
2.
Make sure the foundation is able to absorb vibrations.
3.
Ensure fixings used are suitable for the duty.
4.
Fixing hole size can be found in section 5.3