USF-1600 User Manual
- page 25 -
Function icon
Meaning
Decreasing the value.
Return to the originally set value (100 %).
The
«
Target value
»
and
«
Value change
»
parameters are defined . [
1.
In the main menu, press the button:
⇨
The target value adjustment icons are displayed.
2.
,
or
- Change the value.
⇨
The target value of dispensers is changed:
⇨
The calculator sets the sowing according to the new target value.
g.
Calibration of the speed sensor by a 100-meter section method
If the speed sensor is calibrated using the 100 meter travel method, the number of
pulses that the sensor receives on the 100 meter section should be determined.
When this number of pulses is known, the calculator can calculate the actual speed.
After the first calibration, you can manually enter the number of pulses as the value
of the «
Calibration factor
» parameter.
1.
Drive with the machine onto the field.
2.
Mark the start of the travel on the ground, e.g. place a stone there.
3.
Measure a 100m section in a straight line and mark its end.
4.
In the main menu, press:
>
> (
)
⇨
«
Settings / Speed
»
menu is displayed.
5.
Select the value «
Machine
»
as the
«
Speed source
»
.
Procedure
Procedure