USF-1600 User Manual
- page 26 -
6.
- Activate the
«
Calibration
»
menu.
⇨
The
«
Calibration
»
menu is displayed.
7.
- Start calibration.
8.
Drive to the end of the marked section.
⇨
The counted pulses will be displayed in the «
Number of pulses
» field during
travel.
9.
- Press this button when you reach the end of the section.
⇨
Calibration is ready.
h.
Enter the simulated speed
In order to verify the correct operation of the sensor, you can select the simulated
speed.
WARNING!
Risk of injury when the machine is in motion!
When this function is active, the operator can activate the functions when the
seeder is stopped, although these functions can only be activated when the
machine is driving. People in the vicinity are therefore at risk of injury.
◦
Ensure that nobody is near the machine.
1.
In the main menu, press:
>
> (
)
⇨
The
«
Settings / Speed
»
menu is displayed
2. Select the value
«
Simulation
»
as the
«
Speed source
»
parameter
3. Select the simulated speed as the
«
Simulated speed
»
parameter.
⇨
The simulation will take place at the desired speed
⇨
If you restart the calculator, the simulated speed will be automatically changed to
«0»
.
Procedure