44 GB
when in close proximity to these machines, and the smoke
alarm can't detect smoke in these conditions.
In rooms with a temperature below 0 °C or above 50 °C.
In areas that are extremely dusty, polluted or contaminated
with insects, as particles from the smoke alarm are reduced
during operation.
Mounting location
Install a detector (in every) bedroom and in the hallway
leading to the bedrooms.
Install a smoke alarm in the stairway or on each loor.
Smoke and heat spread horizontally and then rise towards
the ceiling, so a detector should be installed in the middle
of a room.
If the smoke alarm can't be installed in the middle of a room,
it should be installed at least 50 cm from the corners of
the wall.
Install several smoke alarms if the length of the room or
hallway is more than 10 metres.
On a sloped ceiling, the detector must be installed within
50–100 cm of the highest point (see picture B).