:MEASure:OVERshoot?
Command format:
:MEASure:OVERshoot? [<source>]
Functional description:
Measuring overshoot of the specified channel waveform, <source> take value as CHANnel1,
CHANnel2, CHANnel3, CHANnel4 and MATH. Ignore means the current channel.
Return format:
query return1.230e002
,
unit is V.
:MEASure:PREShoot?
Command format:
:MEASure:PREShoot? [<source>]
Functional description:
Measuring prshoot of the specified channel waveform, <source> take value as CHANnel1,
CHANnel2, CHANnel3, CHANnel4 and MATH. Ignore means the current channel.
Return format:
Query return 1.230e-002
,
unit is V.
:MEASure:FREQuency?
Command format:
:MEASure:FREQuency? [<source>]
Functional description:
Measuring frequency of the specified channel waveform, <source> take value as CHANnel1,
CHANnel2, CHANnel3 and MATH. Ignore means the current channel.
Return format:
Query return 2.000e003
,
unit is Hz.
:MEASure:RISetime?
Command format:
:MEASure:RISetime? [<source>]
Functional description:
Measuring rise time of the specified channel waveform, <source> take value as CHANnel1,
CHANnel2, CHANnel3 and MATH. Ignore means the current channel.
Return format:
Query return5.000e-005
,
unit is s.