1. 

Safety Requirements 

This  section  contains information  and  warnings  that  must be followed to  keep  the  instrument  operating 
under safety conditions. In addition, user should also follow the common safety procedures. 
 

Safety Precautions

 

Warning

 

Please follow the following guidelines to avoid possible electric shock and risk 
to personal safety. 

 

Users must follow the following conventional safety precautions in operation, 
service  and  maintenance  of  this  device.  UNI-T  will  not  be  liable  for  any 
personal  safety and  property  loss  caused  by  the  user’s failure  to  follow  the 
following safety precautions. This device is designed for professional users 
and responsible organizations for measurement purposes. 
 
Do  not  use  this  device  in  any  way  not  specified  by  the  manufacturer.  This 
device is only for indoor use unless otherwise specified in the product manual.

 

Safety Statement

 

Warning

 

“Warning” indicates the presence of a hazard. It reminds users to pay attention 
to a certain operation process, operation method or similar. Personal injury or 
death  may  occur  if  the  rules  in  the  “Warning”  statement  are  not  properly 
executed or observed. Do not proceed to the next step until you fully understand 
and meet the conditions stated in the “Warning” statement. 

Caution

 

“Caution” indicates the presence of a hazard. It reminds users to pay attention 
to a certain operation process, operation method or similar. Product damage or 
loss of important data may occur if the rules in the “Caution” statement are not 
properly executed or observed. Do not proceed to the next step until you fully 
understand and meet the conditions stated in the “Caution” statement. 

Note

 

“Note”  indicates  important  information.  It  reminds  users  to  pay  attention  to 
procedures, methods and conditions, etc. The contents of the “Note” should be 
highlighted if necessary. 

Safety Sign

 

 

Danger

 

It  indicates possible  danger  of electric  shock, which  may  cause 
personal injury or death.

 

 

Warning

 

It indicates that you should be careful to avoid personal injury or 
product damage.

 

 

Caution

 

It  indicates  possible  danger,  which  may  cause  damage  to  this 
device or other equipment if you fail to follow a certain procedure 
or condition. If the “Caution” sign is present, all conditions must be 
met before you proceed to operation.

 

 

Note

 

It  indicates  potential  problems,  which  may  cause  failure  of  this 
device if you fail to follow a certain procedure or condition. If the 

Summary of Contents for MSO Series

Page 1: ...Quick Start Guide MSO UPO3000E Series Oscilloscope...

Page 2: ...221130 V1 00 Statement UNI T products are protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pric...

Page 3: ...occur if the rules in the Warning statement are not properly executedorobserved Donotproceedtothenextstepuntilyoufullyunderstand and meet the conditions stated in the Warning statement Caution Caution...

Page 4: ...le tools home appliances etc Household appliances portable tools e g electric drill household sockets sockets more than 10 meters away from CAT III circuit or sockets more than 20 meters away from CAT...

Page 5: ...avoid electric shock the grounding conductor must be connected to the ground This product is grounded through the grounding conductor of the power supply Please be sure to ground this product before i...

Page 6: ...rsonal injury Caution Abnormality If this device may be faulty please contact the authorized maintenance personnel of UNI T for testing Any maintenance adjustment or parts replacement must be done by...

Page 7: ...Not support 3 Getting Started Guide This chapter introduces on using the oscilloscope for the first time the front and rear panels the user interface as well as the built in help system 3 1 General I...

Page 8: ...on the indicator of power soft button on the left corner on the front panel will be extinguished and no function If the power switch on the rear panel is turned on the indicator of power soft button o...

Page 9: ...the oscilloscope s compensating signal and ground terminal respectively Open CH1 and press the AUTO button View the displayed waveform as shown in Figure 2 Excessive Compensation Correct Compensation...

Page 10: ...3 Trigger control TRIGGER 3 Recording waveform 14 Horizontal control HORIZONTAL 4 Jog dial knob 15 Analog channel input port 5 Function menu 16 Vertical control VERTICAL 6 Numeric keypad 17 Menu contr...

Page 11: ...17 5 Rear Panel Figure 4 Rear Panel Table 2 Rear Panel No Description No Description 1 EXT Trig port 5 LAN 2 AUX Out and arbitrary waveform signal output 6 AC Power Input Socket 3 VIDEO Out 7 Power S...

Page 12: ...asily operating system with flexible and high sensitive touch screen features for great waveform display and excellent user experience Touch control function includes tap squeeze drag and drawing rect...

Page 13: ...e Gesture 7 3 Drag Use onefinger to pressanddrag the selected itemto the aimed positionas shownin Figure 9 Drag gesture can use for Drag waveform to change waveform displacement or offset Drag window...

Page 14: ...to one direction this gesture can quickly turn on off time measurement and voltage measurement cursor a Time measurement cursor Slide down in vertical to directly turn on time measurement cursor as s...

Page 15: ...e menu This symbol represents that multipurpose knob on the front panel can be used to select and adjust parameter This symbol represents that there are several options This symbol represents that the...

Page 16: ...steps restart the oscilloscope e If the instrument still cannot work please contact UNI T 2 After signal acquisition signal of waveform does not appear on the screen a Check whether BNC port is conne...

Page 17: ...trigger is normal and the current time base is slow e All the preceding causes slow refreshing of waveforms Users can restore the factory settings so that the waveforms can be refreshed normally 11 Ap...

Reviews: