Quick Start Guide                                                                                                                                                              MSO/UPO3000E Series Oscilloscope 

 

Instruments.uni-trend.com                                                                                                                                                                                           

  14 / 17 

 

Select “Area A”:   

 

Drawing the area of trigger area A; 

 

Open trigger area A; 

 

Open “trigger area” menu.   

Select “Area B”:   

 

Drawing the area of trigger area B;   

 

Open trigger area B;   

 

Open “trigger area” menu.     

   

Hints: Press “drawing rectangle” icon to switch drawing rectangle and operating waveform mode. Press 

“drawing rectangle” icon, if icon displays 

, which presents the drawing rectangle mode is opened; 

press “drawing rectangle” icon, if icon displays 

, which presents the operating waveform mode is 

opened. Operating waveform mode of the oscilloscope is enabled by default. 

7.5 Touch Shortcut Operating 

Separate two fingers and meanwhile slide two fingers to one direction, this gesture can quickly turn on/off 
time measurement and voltage measurement cursor. 

 

a.

 

Time measurement cursor   

 

Slide down in vertical to directly turn on time measurement cursor as shown in Figure 11 (a); 

 

Slide up in vertical to directly turn off time measurement cursor; 

b.

 

Voltage measurement cursor   

 

Slide right in horizontal to directly turn on voltage measurement cursor as shown in Figure 11 (b); 

 

Slide left in horizontal to directly turn off voltage measurement cursor; 

 
Note: Turn on/off cursor requires that slide distance should be 

3div. 

 

         

   

(a)                                                                                                    (b) 

Figure 11 

c. Quick Guide 
When the oscilloscope is stop, touch and drag the T identifier to left or right around quickly, or rotate the 
horizontal Position knob, a quick guide icon will displayed at the top of the screen, as shown in Figure 12. The 
quick  guide  icon  can  be  closed  when  the  oscilloscope  is  operating.  In  quick  guide,  the  oscilloscope  will 

Summary of Contents for MSO Series

Page 1: ...Quick Start Guide MSO UPO3000E Series Oscilloscope...

Page 2: ...221130 V1 00 Statement UNI T products are protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pric...

Page 3: ...occur if the rules in the Warning statement are not properly executedorobserved Donotproceedtothenextstepuntilyoufullyunderstand and meet the conditions stated in the Warning statement Caution Caution...

Page 4: ...le tools home appliances etc Household appliances portable tools e g electric drill household sockets sockets more than 10 meters away from CAT III circuit or sockets more than 20 meters away from CAT...

Page 5: ...avoid electric shock the grounding conductor must be connected to the ground This product is grounded through the grounding conductor of the power supply Please be sure to ground this product before i...

Page 6: ...rsonal injury Caution Abnormality If this device may be faulty please contact the authorized maintenance personnel of UNI T for testing Any maintenance adjustment or parts replacement must be done by...

Page 7: ...Not support 3 Getting Started Guide This chapter introduces on using the oscilloscope for the first time the front and rear panels the user interface as well as the built in help system 3 1 General I...

Page 8: ...on the indicator of power soft button on the left corner on the front panel will be extinguished and no function If the power switch on the rear panel is turned on the indicator of power soft button o...

Page 9: ...the oscilloscope s compensating signal and ground terminal respectively Open CH1 and press the AUTO button View the displayed waveform as shown in Figure 2 Excessive Compensation Correct Compensation...

Page 10: ...3 Trigger control TRIGGER 3 Recording waveform 14 Horizontal control HORIZONTAL 4 Jog dial knob 15 Analog channel input port 5 Function menu 16 Vertical control VERTICAL 6 Numeric keypad 17 Menu contr...

Page 11: ...17 5 Rear Panel Figure 4 Rear Panel Table 2 Rear Panel No Description No Description 1 EXT Trig port 5 LAN 2 AUX Out and arbitrary waveform signal output 6 AC Power Input Socket 3 VIDEO Out 7 Power S...

Page 12: ...asily operating system with flexible and high sensitive touch screen features for great waveform display and excellent user experience Touch control function includes tap squeeze drag and drawing rect...

Page 13: ...e Gesture 7 3 Drag Use onefinger to pressanddrag the selected itemto the aimed positionas shownin Figure 9 Drag gesture can use for Drag waveform to change waveform displacement or offset Drag window...

Page 14: ...to one direction this gesture can quickly turn on off time measurement and voltage measurement cursor a Time measurement cursor Slide down in vertical to directly turn on time measurement cursor as s...

Page 15: ...e menu This symbol represents that multipurpose knob on the front panel can be used to select and adjust parameter This symbol represents that there are several options This symbol represents that the...

Page 16: ...steps restart the oscilloscope e If the instrument still cannot work please contact UNI T 2 After signal acquisition signal of waveform does not appear on the screen a Check whether BNC port is conne...

Page 17: ...trigger is normal and the current time base is slow e All the preceding causes slow refreshing of waveforms Users can restore the factory settings so that the waveforms can be refreshed normally 11 Ap...

Reviews: