16
(7) Align the cylinder with the mark, and insert in the cup packing.
(8) Remove the head cover gasket and wash the head cover. After washing, blow with
compressed air, and fit the new gasket.
(9) Insert the head cover joint in the connecting tube and align the screw holes in the
casing and head cover. Tighten the four M6xL30 hex-headed bolts to a torque 8Nm.
When replacing the connecting tube, ensure that the replacement tube is cut to the
same pump length.
(10) Fit the connecting tube. (When replacing the connecting tube, ensure that the
replacement tube is cut to the same pump length.)
(11) Lay the pump on its side and fit the panel and handle.
(12) Replacement of consumables is now complete (fit the angle to complete replacing
consumables in the vertical type pump).
(7)
Inserting the cylinder.
(8)
Replacing the gasket.
(9)
Fitting the head cover.
(10)
Fitting the connecting tube.
(11)
Fitting the panel and handle.
(12)
Replacement of consumables complete.