DC Power
【
DC-10/DC-20
】
5. How to Operate
44
Table 5-3: Output parameter (limit value, ignition voltage, timer, etc.)
No
Description
Hierarchically
Setting rage
Variable
width
Unit
Initial value
1
Setup of the limit value
of the output power.
CNFG/LIMT/POWR
0
~
(α×20
+
β×10)kW
0.1
kW
Rated value*1
2
Setup of the limit value
of the output voltage.
CNFG/LIMT/VOLT
800V model
:
0
~
800V
1000V model
:
0
~
1000V
1
V
800
1000
3
Setup of the limit value
of the output current.
CNFG/LIMT/CRNT
800V model
:
0
~
(α×50
+
β×25)A
1000V model
:
(0
~
(α×40.0
+
β×18.0)A)
0.1
A
Rated value*2
4
Setup of ignition voltage CNFG/OTHR/IG V
800V model
:
800
~
1500
1000V model
:
1000
~
1500
1
V
1500
5
Setup of set point light
up range
CNFG/OTHR/SETP
2
~
8
1
%
2
6
Setup of whether or not
to use the ramp function
FUNC/RAMP/MODE
DISBL/ENABL
―
―
DISBL
7
Setup of the rise time
from the start of ramping
to the command value
FUNC/RAMP/TIME
0.05
~
600
0.01
s
0.05
8
Setup of the initial value
for the start of ramping
FUNC/RAMP/STRT
0
~
100
1
%
0
*1, 2: It depends on the power configuration.
ex. combination of two DC-20 units and one DC-10 unit = 50-kW
*1 (2×20
+
1×10)=50kW *2 (2×50
+
1×25)=125A