DC Power
【
DC-10/DC-20
】
2. Overview
8
Table 2-6. HARTING connector pin assignment at the cable side of input section
Connector Pin Number
Connection destination
A
L1(R phase)
B
L2(S phase)
C
L3(T phase)
frame
GND
2-5-2. Connection of output section
As with the input section, a [HARTING] connector is employed also in the output section.
Although the genuine cable can be purchased from us, if you prepare a cable by yourself, purchase
connector component parts with reference to the items of [Table 2-7. HARTING connector
configuration at the cable side of output section], select a suitable wiring material, and complete the
installation.
A special tool is required. Contact the manufacturer for the details of installation conditions etc.
When selecting a wiring material used for the cable, refer to [Table 2-2. Electrical specification], and
select the one that would satisfy the rating specification.
In addition, select a suitable cable ground based on the line shape of the wiring material selected.
Figure 2-3. Assignment of output connector at the product side(Common to DC-5-P and DC-10-P)
Table 2-7. HARTING connector configuration at the cable side of output section
Name
Model
Q’ty
Han 70A crimp module,male
09 14 002 3041
1
Carrier hood
09 14 001 0311
1
Hood Top Entry M25
72 14 001 0401
1
70A contact,male 10mm2
09 11 000 6131
2
Ferrule
6mm2 L=12
1
Table 2-8. HARTING connector pin assignment at the cable side of output section
Connector Pin Number
Connection destination
1
Cathode
2
Anode
It is recommended to use our cable for I/O cables.
We shall not take any responsibility on malfunctions and defects as a result of
using a cable which is prepared by the customers. Please acknowledge
beforehand.
Cathode
Anode
Shield
CAUTION
Summary of Contents for DC-10
Page 88: ......