DC Power
【
DC-10/DC-20
】
2. Overview
6
Table 2-3: Electrical specification; 1000V
Item
Specifications
Model
DC-10-H
DC-20-H
In
p
u
t
s
p
e
c
ifi
c
a
ti
o
n
Rated input voltage
AC208V
AC208V
Input voltage variation
range
AC187V
~
229V
Number of phases /
Frequency
Three-phase for 50/60Hz
Input connection
Connector
Input current
50A or less*1
80A or less*1
Input capacity
13.5 kVA or less*1
25 kVA or less*1
Leakage current
5 mA or less
Efficiency
87
%
or more*2
87
%
or more*2
Power factor
0.85 or more*2
0.92 or more*2
O
u
tp
u
t
s
p
e
c
if
ic
a
ti
o
n
Rated power
10kW
20kW
Rated current
18A
40A
Rated voltage
1000V
※
3
1000V
※
3
Ignition voltage
1500V
1500V
Output range
10kW
V1
1500V
1A
I4
Standard
S specifications
V2
1000V
V3
555V
V4
200V
V5
100V
5A
I1
10A
I2
18A
I3
20kW
V1
1500V
2A
I4
Standard
S specifications
V2
1000V
V3
500V
V4
200V
V5
100V
5A
I1
20A
I2
40A
I3
V1
1500V
V1
1500V
V2
1000V
V2
1000V
V3
555V
V3
500V
V4
200V
V4
200V
V5
100V
V5
100V
I1
5A
I1
5A
I2
10A
I2
20A
I3
18A
I3
40A
I4
1A
I4
2A
Output polarity
Negative polarity
ARC control
Inverter stops when an unusual electrical discharge is detected *4.
Output connection
Connector
Con
tro
l
Control mode system
LOCAL control / USER control / SERIAL communication control (RS232C or RS485)
Output control system
Constant power control (P control) / Constant current control (I control) / Constant voltage
control (V control)
Control accuracy
The higher of ±0.5% or less of the rated output or ±1% of the set value
Guaranteed control
range
Constant power control: 10 to 100% of the rated power value
*1: This depends on the working condition at your site.
*2: This depends on an input voltage of 187 to 229 VAC. This may depend on the equipment on the input
side.
*3: When a device for preventing unusual electrical discharge is used, the output voltage is limited to
800V.
*4: A low arc energy circuit can be installed as an option. When a device for preventing unusual electrical
discharge is used, only the inverter stops.