background image

 

 
© 12/2006 UltraVolt HV Rack System Installation and Operators Manual, Rev A 

20 of 23 

APPENDIX A 

 

SPECIFICATIONS 
 

 

CAUTION:

 

ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 
CUSTOMERS ARE NOT NOTIFIED WHEN CHANGES OCCUR UNLESS THEY 
HAVE ARRANGED FOR CONFIGURATION CONTROL WITH ULTRAVOLT’S 
CUSTOMER SERVICE DEPARTMENT (“CSD”) THROUGH THE “-Q” SUFFIX 
PROGRAM. ONLY THOSE ITEMS OF GREATEST SIGNIFICANCE WILL BE 
POSTED ON ULTRAVOLT’S WEB SITE, IN THE PRODUCT-CHANGE NOTICE 
SECTION.

 

 

Since each channel of the 

UltraVolt HV Rack

®

 system is custom configured with a specific model of 

UltraVolt

®

 

high-voltage power supply, the end user should refer to UltraVolt’s datasheet for the electrical specifications of that 
model. 
 

Storage Temperature 

Storage temperature range is -55C° to +105C°. 

 

Operating Altitude, Humidity & Temperature: 

UltraVolt HV Rack

 Series operating performance is guaranteed between sea level and 10,000ft in non-

condensing relative humidity up to 95% between temperatures of +10°C and +40°C.  

 
Shock and vibration 

TBD 

 

AC Power 

The AC input power is universal auto-ranging. It operates between 85 to 250VAC at 47 to 63Hz. The power 
entry module is EMI/RFI-filtered, IEC 320/C20 inlet. 

 

Fuse 

AC power is fused through a 5mm x 20mm, time-delay fuse located on the rear panel. The fuse must always be 
replaced with the same type and rating, as per the 

UltraVolt HV Rack

 power supply’s rating label. 

 

HV connectors 

The 

UltraVolt HV Rack

 system is equipped with a configurable output plate for each high-voltage output 

channel. Each rack can have custom-configured high-voltage output and return connectors, according to 
customer requirement. The basic 

UltraVolt HV Rack

 system includes Alden B110US 40kV industrial high-

voltage output connectors and a two-way binding post return for each channel.   

 
Package 

Chassis dimensions: 17.00” wide x 18.50” deep x 5.00” high (431,8 x 469,9 x 127,0mm). Width is measured 

chassis side to opposite side; depth is measured from the back of the front-panel mounting flange to chassis 
rear and does not include rear-panel connector protrusion; height is measured chassis top to chassis bottom 
and does not include the height of rubber feet mounted on the bottom. 

 
Front-panel dimensions: 19.00” wide x 0.125” deep x 5.25” high (3U) (482,60 x 3,18 x 133,35mm). These 

measurements do not include handles or controls. Front-panel mounting holes are configured for both #10-32 
and M6 rack configurations. 

 
Weight: Approximately 30 pounds (11,2kg), configuration dependent; approximately 40 pounds (14,93kg) 

shipping. 

 

 

 

 

 

 

 

 

 
 

Summary of Contents for HV RACK

Page 1: ...12 2006 UltraVolt HV Rack System Installation and Operators Manual Rev A 1 of 23 HV RACK POWER SUPPLY INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL...

Page 2: ...Part 4 Electrical Connections Cables and Interconnects 10 Typical System Wiring Diagram 11 Part 5 Controls and Indicators Features 12 Front Panel Controls and Indicators 12 Rear Panel Connections Cont...

Page 3: ...external system device chassis should be connected to the HV Rack system s rear panel system grounding stud Do not operate without protective covers in place To avoid electric shock or fire hazard do...

Page 4: ...damage to equipment or other property DANGER Danger statements identify conditions or practices that present an immediate danger and if not avoided will result in personal injury or loss of life Atte...

Page 5: ...goods that are shown to be defective during the warranty period The cost of any repairs made by the Seller to goods no longer covered by this warranty shall be borne by the Buyer The Buyer must conta...

Page 6: ...lity Bench top or rack mount installation Universal AC power input UltraVolt s HV Rack power supply is designed to meet numerous high tech high voltage performance requirements It is well suited for u...

Page 7: ...DY ENOUGH TO SUPPORT ITS WEIGHT WARNING DO NOT OPERATE THE ULTRAVOLT HV RACK SYSTEM ON A METAL OR CONDUCTIVE BENCH TOP SURFACE FAILURE TO FOLLOW THIS WARNING CAN RESULT IN PERSONAL INJURY OR LOSS OF L...

Page 8: ...ull the chassis inside section free 3 UltraVolt s HV Rack system is equipped with PEM nut mounting patterns on both sides to mount the rack slides chassis sections Mount the chassis inside sections to...

Page 9: ...ess and hold the button safety locks on the inside sections and fully collapse the slide sections easing the UltraVolt HV Rack power supply into place 8 Secure the UltraVolt HV Rack power supply front...

Page 10: ...all channels Voltage Programming Dial Set to 0 Current Programming Dial Set to 0 Channel Enable Button HV ON Set to OFF out Connect external cable assemblies as required depending upon the specific a...

Page 11: ...12 2006 UltraVolt HV Rack System Installation and Operators Manual Rev A 11 of 23 TYPICAL SYSTEM WIRING DIAGRAM...

Page 12: ...line and a remote indicator to show when the rear panel Remote Control Selector DIP Switch is in the remote position Local setting enables all front panel controls remote setting transfers all operati...

Page 13: ...ng the output depending on the status of HV ON HV ON switch item 11 7 Current Monitor Current Preset Meter Each channel has a 4 digit LED display to indicate either actual output current or preset cur...

Page 14: ...A rear panel remote local control DIP switch can be used to enable remote control by transferring front panel control and programming functions to the 37 pin D connector on the rear panel The followi...

Page 15: ...eeding 91V UltraVolt recommends using a ring lug to secure the HV return so it cannot inadvertently become disconnected 8 Cooling Fan The HV Rack power supply has four cooling fans mounted on the rear...

Page 16: ...is obtained as displayed on the Voltage Monitor Voltage Preset Meter While still holding the Current Voltage Preset Switch adjust the Current Programming Dial until the desired current is obtained as...

Page 17: ...gh voltage output It performs the same function as the front panel switch HV ON When a channel is remotely enabled the Channel Output Enable Switch HV ON for that channel will illuminate Output voltag...

Page 18: ...gnal Ground A B C D This is signal return ground for Channel A B C D In addition to individual channel I O control and status signals there is a Global Disable signal Global Disable channels A B C and...

Page 19: ...tomer Service Department to speak with an Applications Engineer ROUTINE CLEANING All ventilation openings top bottom sides and rear panel should be checked periodically and kept free of dust and other...

Page 20: ...ered IEC 320 C20 inlet Fuse AC power is fused through a 5mm x 20mm time delay fuse located on the rear panel The fuse must always be replaced with the same type and rating as per the UltraVolt HV Rack...

Page 21: ...d B 14 Signal Ground B Signal Ground for Channel B 15 Remote Enable C Input TTL high to enable low to disable Channel C Default is disable via internal pull down 16 Remote Voltage Adj C Input Voltage...