© 12/2006 UltraVolt HV Rack System Installation and Operators Manual, Rev A 

8 of 23 

RACK MOUNT INSTALLATION 
 

 

CAUTION:

 

CHASSIS SLIDE RAILS ARE RECOMMENDED WHEN INSTALLING THE 
ULTRAVOLT 

HV RACK

®

 SYSTEM IN AN INDUSTRIAL RACK. THE 

HV RACK

 

POWER SUPPLY SHOULD NOT BE MOUNTED OR SUPPORTED BY THE FRONT 
PANEL ALONE IF SUBJECTED TO HIGH VIBRATION OR SHOCK AS MIGHT 
OCCUR IN A MOBILE ENVIRONMENT, OR DURING TRANSPORT. 

 

CAUTION: 

THE SLIDE RAILS AND MOUNTING HARDWARE SHOULD BE OF A TYPE 
OBTAINED THROUGH OR RECOMMENDED FOR USE BY ULTRAVOLT. USE OF 
INCORRECT SLIDE RAILS OR HARDWARE CAN RESULT IN PERSONAL 
INJURY AND/OR DAMAGE TO THE EQUIPMENT OR OTHER PROPERTY. 

 

CAUTION: 

ULTRAVOLT’S 

HV RACK

 POWER SUPPLY MUST ONLY BE INSTALLED AND 

OPERATED IN A LOCATION WHERE ADEQUATE VENTILATION IS ASSURED.   

 

Should the end user decide to install the 

UltraVolt HV Rack

 power supply in an industrial 19” rack, UltraVolt 

recommends using slide rails. The slide rails and mounting hardware should be of a type obtained through or 
recommended for use by UltraVolt and correctly sized to support the weight of the 

UltraVolt HV Rack

 power 

supply. Additionally, the screws used to attach the slide rails to either side of the 

HV Rack

 power supply must 

be of the correct length to prevent contact with internal components.  

 

Each slide kit contains 1 pair of slides for the left and right side of the chassis. The slides are symmetrical and 
individual components can be used interchangeably. Each slide kit consists of four brackets, two slide sections 
(including  two chassis inside sections), and hardware (figures 1, 2 and 3). 
 

†

 

1) Fully extend each chassis slide assembly, pulling the chassis inside section (item 1) outwards until the 
chassis and the intermediate sections (item 2) lock into place. 

†

 

2) Remove the chassis section by grasping the slide assembly and pressing the button lock on the outside of 
the chassis inside section. Pull the chassis inside section free.  

†

 

3) UltraVolt’s

 HV Rack

 

system is equipped with PEM nut-mounting patterns on both sides to mount the 

rack slides’ chassis sections. Mount the chassis inside sections to each side of the 

UltraVolt HV Rack

 

power-supply chassis with four (4) each of the supplied 10-32x1/4 pan-head machine screws (item 10). 
When doing so, ensure the button stop on the end of the chassis inside section is oriented towards the rear of 
the system (figure 1). 

†

 

4) Assemble the front-end brackets (item 4) to the outside of each slide (item 3) with four (4) supplied 10-
32x1/2 pan-head machine screws, four (4) flat washers (item 15), and four (4) 10-32 locking nuts (item 21). 
Before tightening, ensure the two sections are aligned straight with one another and that the distance 
between the forward end of the front bracket and the forward end of the slide measures 3.89”, as indicated 
(figure 2). Tighten all hardware. 

†

 

5) Install the rear-end brackets (item 4) to the outside of each slide (item 3) with four (4) supplied 10-32x1/2 
pan-head machine screws, four (4) flat washers (item 15), and four (4) 10-32 locking nuts (item 21). Do not 
tighten at this time.  

†

 

6) Determine the height at which UltraVolt’s

 HV Rack

 

system is to be positioned in the industrial rack. 

Position and hold the previously assembled slide section with two attached end brackets in place, with the 
right angle slotted flange towards the inside edges of the industrial rack. Slip a 10-32x1/2 screw (item 11) 
through the front of the industrial rack-mounting edge and through the front slotted end flange. Secure with 
a split ring locking washer (item 16) and a nut (item 20), capturing the slotted flange between the nut and 
industrial rack-mounting inside edge. Repeat this for the rear bracket. Double up the fasteners on both the 
front and rear mounting screws; two screws in front and two in back for each side. Tighten all hardware.   

  

†

 

7) Fully extend and lock the slide into place. With the help of an assistant, lift the 

UltraVolt HV Rack

 

power supply, aligning the chassis inside sections with the extended slide sections and slip into place. Then, 

Summary of Contents for HV RACK

Page 1: ...12 2006 UltraVolt HV Rack System Installation and Operators Manual Rev A 1 of 23 HV RACK POWER SUPPLY INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL...

Page 2: ...Part 4 Electrical Connections Cables and Interconnects 10 Typical System Wiring Diagram 11 Part 5 Controls and Indicators Features 12 Front Panel Controls and Indicators 12 Rear Panel Connections Cont...

Page 3: ...external system device chassis should be connected to the HV Rack system s rear panel system grounding stud Do not operate without protective covers in place To avoid electric shock or fire hazard do...

Page 4: ...damage to equipment or other property DANGER Danger statements identify conditions or practices that present an immediate danger and if not avoided will result in personal injury or loss of life Atte...

Page 5: ...goods that are shown to be defective during the warranty period The cost of any repairs made by the Seller to goods no longer covered by this warranty shall be borne by the Buyer The Buyer must conta...

Page 6: ...lity Bench top or rack mount installation Universal AC power input UltraVolt s HV Rack power supply is designed to meet numerous high tech high voltage performance requirements It is well suited for u...

Page 7: ...DY ENOUGH TO SUPPORT ITS WEIGHT WARNING DO NOT OPERATE THE ULTRAVOLT HV RACK SYSTEM ON A METAL OR CONDUCTIVE BENCH TOP SURFACE FAILURE TO FOLLOW THIS WARNING CAN RESULT IN PERSONAL INJURY OR LOSS OF L...

Page 8: ...ull the chassis inside section free 3 UltraVolt s HV Rack system is equipped with PEM nut mounting patterns on both sides to mount the rack slides chassis sections Mount the chassis inside sections to...

Page 9: ...ess and hold the button safety locks on the inside sections and fully collapse the slide sections easing the UltraVolt HV Rack power supply into place 8 Secure the UltraVolt HV Rack power supply front...

Page 10: ...all channels Voltage Programming Dial Set to 0 Current Programming Dial Set to 0 Channel Enable Button HV ON Set to OFF out Connect external cable assemblies as required depending upon the specific a...

Page 11: ...12 2006 UltraVolt HV Rack System Installation and Operators Manual Rev A 11 of 23 TYPICAL SYSTEM WIRING DIAGRAM...

Page 12: ...line and a remote indicator to show when the rear panel Remote Control Selector DIP Switch is in the remote position Local setting enables all front panel controls remote setting transfers all operati...

Page 13: ...ng the output depending on the status of HV ON HV ON switch item 11 7 Current Monitor Current Preset Meter Each channel has a 4 digit LED display to indicate either actual output current or preset cur...

Page 14: ...A rear panel remote local control DIP switch can be used to enable remote control by transferring front panel control and programming functions to the 37 pin D connector on the rear panel The followi...

Page 15: ...eeding 91V UltraVolt recommends using a ring lug to secure the HV return so it cannot inadvertently become disconnected 8 Cooling Fan The HV Rack power supply has four cooling fans mounted on the rear...

Page 16: ...is obtained as displayed on the Voltage Monitor Voltage Preset Meter While still holding the Current Voltage Preset Switch adjust the Current Programming Dial until the desired current is obtained as...

Page 17: ...gh voltage output It performs the same function as the front panel switch HV ON When a channel is remotely enabled the Channel Output Enable Switch HV ON for that channel will illuminate Output voltag...

Page 18: ...gnal Ground A B C D This is signal return ground for Channel A B C D In addition to individual channel I O control and status signals there is a Global Disable signal Global Disable channels A B C and...

Page 19: ...tomer Service Department to speak with an Applications Engineer ROUTINE CLEANING All ventilation openings top bottom sides and rear panel should be checked periodically and kept free of dust and other...

Page 20: ...ered IEC 320 C20 inlet Fuse AC power is fused through a 5mm x 20mm time delay fuse located on the rear panel The fuse must always be replaced with the same type and rating as per the UltraVolt HV Rack...

Page 21: ...d B 14 Signal Ground B Signal Ground for Channel B 15 Remote Enable C Input TTL high to enable low to disable Channel C Default is disable via internal pull down 16 Remote Voltage Adj C Input Voltage...

Page 22: ...and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in...

Page 23: ...12 2006 UltraVolt HV Rack System Installation and Operators Manual Rev A 23 of 23 APPENDIX D ULTRAVOLT S HV RACK SYSTEM BLOCK DIAGRAM...

Reviews: