UTT-110B VOIP Gateway (SIP)
User manual
Copyright
©
2013, Shenzhen Ultrative Technologies Co., Ltd All rights reserved
24
No conversion
example
In
6xxx
call rules, for example, explain number conversion
number conversion by
A (addition), D (delete), C (change)
change
the number in three ways:
A (addition):
There may be an increase in the number of
call rules, such as call rules
6xxx,
the number is converted
to
(a0755) 6xxx,
when a user dials
6002,
after sending out a number
of transform
07,556,002;
(Note: when necessary, call rules A front
inside any character can fill
(a +
p)).
D
(delete):
You can delete the rule in which the
callnumbers, such as call rules
6xxx,
the number is converted to6x
(d) x,
it means that the third deleted when users dial the
number
6002
transformed sent out after the number of
602; (
Note: A
number may be a need to remove the direct conversion
of (d), followed by
d
without adding deletecontent)
C (c
hange): to change the rules on the inside callnumbers, such
as the number dialed rules
6xxx,
the number is converted to
6xx
(c99),
sent out after transformation rules when users
dial
6002
number is
60099
(Note: when necessary,Any character
can be changed by calling the rules inside(c +
content))
D
(delete)
and
C (change)
represents one of the rules which call
regular character, and
A (addition)
is added in front of the character
in a certain call rules can also be combined,such as call
rules
6xxx,
number conversion to
(a0755) 6x (d) (c99)
(a111),
sent
out when the user dials the converted number is6002
07556099111.
6x (d) (c99)
is carried out at the number of
transformation
6xxx are 4 ,
the number of bits to be consistent.
3.5 Port Settings
Click Port Settings:
Figure3-10 Port Setting Interface
All manuals and user guides at all-guides.com