Think
UltraSource
First
. • [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
4.5
MAINTENANCE
Supervisor Menu on Digital Panel
Untrained personnel should not alter any setting in the supervisor menu.
Figure 4.4
WAITTIME: 3
CUTTIME: 1
PREVAC: 15
RUNNING PROG: 1
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
-
+
-
+
-
+
-
+
The following are parameters that can
only be set in the supervisor menu.
This is the Main Menu screen. When
the machine starts up, the last program
that was run will be the current program
shown in the window.
Press and hold down both arrow keys for
at least 3 seconds to enter the supervisor
menu.
NOTE:
If your machine is not installed
with the precut option, disregard the
PREVAC, CUTTIME, and WAITTIME
parameters.
PREVAC is the % vacuum that you wish to reach
before activating the knife, which makes slits in
the bag for precut. Use the UP or DOWN arrow
keys to change the current setting.
The range is from 5% to 20% vacuum.
Press the MENU key.
CUTTIME is the number of seconds that the
seal valve is activated. This is the time when the
knife actually makes the evacuation slits in the
bag/pouch for precut. The range is from 0 to 3
seconds.
Press the MENU key.
WAITTIME is the number of seconds the machine
waits for the knife to retract before resuming the
vacuum cycle. The range is from 0 to 6 seconds.
Press the MENU key.