Think
UltraSource
First
. • [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 • 800.777.5624 • 816.753.2150
4.2
MAINTENANCE
MAINTENANCE
Step
1.
Remove the seal bars from the machine. Pull
off the Teflon
®
tape strip and discard. Clean
off any remaining Teflon
®
tape adhesive
using acetone or an equivalent solvent.
Step
2.
Using a 2mm Allen wrench, loosen the set
screws for the cut-off wire and the seal
element on both ends of the seal bar and
discard.
Step 3.
If you are replacing the L-shaped spring retainer and the spring at this time, loosen the set
screw and remove the old spring retainer and spring and install the new ones. Adjust the
spring retainer to allow an 1/8-in. gap between the spring retainer and the seal bar. This
will allow the seal element to remain under tension after tightening the seal element.
TEFLON
TAPE
CUT-OFF
WIRE
SEAL ELEMENT
SET SCREW
2mm ALLEN
WRENCH
TIGHTENING
TOOL
BRASS CONTACT
SLOTTED TIP
SCREWDRIVER
Vacuum Pump Maintenance
Consult the pump manufacturer’s manual provided with the machine for detailed
information.
Seal Bar Maintenance
The following illustrations show replacement of the seal elements for the seal bars.
Figure 4.1
Figure 4.2
Figure 4.3
Teflon
®
tape
Seal element
Set screw
2mm Allen
wrench
Cut-off wire
Brass contact
Slotted tip
screwdriver
Tightening
tool
Summary of Contents for Ultravac 500
Page 2: ......
Page 69: ...9 ...
Page 70: ...10 ...
Page 72: ...12 13 ...
Page 80: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 81: ...22 ...