These programs are only suitable for charging and discharging lithium
batteries with a nominal voltage of 3.7V, 3.3V and 3.6V per cell. These
batteries need to adopt different charge technique which is termed as
constant voltage(CV) and constant current(CC) method. The charge
current varies according to the battery capacity and performance. The
final voltage of charge process is also very important; it should be
precisely matched with the charge voltage of the battery. They are
4.2V for LiPo, 3.6 V for LiFe, and 4.1V for Lilon. The charge current
and nominal voltage as for cell count set on the charge program must
always be correct for the battery to be charged.
CHARGING LITHIUM BATTERY AT BALANCE MODE
This function is for balancing the voltage of lithium-polymer battery
cells while charging.
In the balance mode, the battery needs to connect to the battery's
power lead with balance wire.
In this mode, the charging process will be different from ordinary
charging mode. The internal processor of the charger will monitor the
voltages of each cell of the battery pack and control charging current
which is feeding to each cell to equalize the voltage.
Note: We recommend charging lithium batteries with a balance wire in
the balance mode only.
-
-
+
+
Start
Enter
Batt type
Stop
>3 seconds
The left side of the first line shows the type
of battery you choose. The value on the left
of the second line of the charger is current
the user sets. After setting the current and
voltage, press the START/ENTER button for
more than 3 seconds to start the process.
DEC. INC.
DEC. INC.
LITHIUM BATTERY(LiPo/LiFe/LiIon)PROGRAM
13