INSTALLATION WARNINGS 

 

 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning 

use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. 

Cleaning and user maintenance shall not be made by children without supervision. 

 

All-pole disconnection from the supply is required, incorporated in the fixed wiring. Switches intended to ensure all-pole 

disconnection must be directly connected with the supply terminals and must have a contacts distance of at least 3 mm 

in each pole. 

 

Electrical towel rail must not be installed with the MOBUS regulating box located at the top. This can seriously damage 

the control box and create a dangerous situation with a risk of fire. 

 

Follow the conventional colours for wiring operations if no plug is present.

 

Brown

 

Live Wire

 

Blue

 

Neutral Wire

 

Yellow - Green

 

Earth

 

 

 

The electricity supply must be adequate to support the required power. 

 

Protect the electricity supply with an RCCB (Residual Current Circuit Breaker) device. 

 

All metallic parts of the electrical towel rail fitted with MOBUS and powered must not exceed the temperature limits 

according to the applicable standard EN 60335-2-43 also in case of broken capillary thermostat control that 

continuously powers the heating element. 

 

MOBUS yellow/green earth wire must be connected to the corresponding yellow/green ground wire of the electricity 

supply at the mains. (THIS PRODUCT MUST BE EARTHED) 

 

Don’t use the MOBUS regulating box to lean the electrical towel rail on the floor as you can damage the plastic and 

water can penetrate inside with a risk of electrical shock. 

 

The electrical heating element must be permanently connected to a suitable electricity supply by way of the cable 

provided. This should be via a fused spur in accordance with the IEE Wiring Regulations (BS7671). If sited in the 

bathroom, the Fused Connection Unit must be located out of reach of persons using the basin, shower or bath. If in 

doubt, consult a qualified electrician. 

 

Connect the MOBUS control unit to the mains using a BS Fused Connection Unit. 

 

The Fused Connection Unit should be fitted with a 5 Amps fuse to BS1362. 

 

TOWEL RAIL INSTALLATION WARNINGS 

 

 

The Towel rail has to be mounted parallel to the wall using the brackets recommended by the towel 
rail manufacturer. The distance between MOBUS and  the wall must be between 60 and 90 mm (Fig. 2). 

In order to avoid a hazard for younger children,  the electrical towel rail should be installed so that its 
bottom part is at least 600mm above the floor according to EN 60335-2-43/A1.

 

 

MOBUS must be fitted to the towel rail before mounting the rail to the wall.

 

 

Wrap a small quantity of  PTFE tape around the MOBUS heating element thread and the

 

T-piece thread (in case of Dual Fuel installation).

 

 

Make sure that the towel rail is fitted with a component (like 3BAR Valve) which limits the risk of 
excessive pressure.

 

Fig. 2

 

 
 

 
 

 

Fig. 3 

3 bar valve

 

 

The 3BAR valve (Fig. 3) must be installed on the top part of the towel rail.

 

In case of ‘Dual fuel’ installation, a T-piece of 40mm maximum length (male thread excluded) 

is required.

 

 

The Spacer (B) must not be hit, moved or removed during the installation of the towel

 

heater  (electric only MOBUS  installation).

 

 

The Spacer must not be torn, and must show no imperfections.

 

 

  

 

  

 

Summary of Contents for MOBUS

Page 1: ...sing the button to increase or to reduce rail temperature Again allow 30 45 mins for these changes to take effect This power setting will be stored in the controller memory In the event of a power failure this setting will be lost it will be necessary to re programme the unit Timer Eco function When the Eco key is pressed the Power LED turns GREEN The heater is powered for a period of 120 mins the...

Page 2: ...RPROFESSIONAL INSTALLER ONLY The image isfor illustration purposes only SUPPLIED PARTS IN EACH PACKAGING MOBUS I 2 spacer I Instruction leaflet APPLICABLE EUROPEAN STANDARD Electrical tests according to CEI EN 60335 1 Applicable directives 2011 65 EU RoHS Directive 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directive COD 571357670 REV 06 2015 ...

Page 3: ...refully selected in proportion to function of the towel rail size and thermal output ToselectMOBUS electrical power please refer to the towel rail manufacturer instructions when a certification related to the complete system according to EN 60335 2 43 issued by an European recognized institute like SEMKO VDE IMQ is available In caseof missing towel rail manufacturer certification refer to EN 60335...

Page 4: ...he top part of the rail in the opposite side where the MOBUS is installed In case of valve intervention it is quite normal for liquid relief and water excess to possibly reach the floor Please take this aspect into consideration In Dual fuel installation with central heating and MOBUS at least one of the rail valves must always be left open when the electrical element is switched on For all other ...

Page 5: ...on IPX4 Operating Ambient Temperature 0 C 40 C Storage Temperature 20 C 80 C Max Humidity Level 85 at 25 C without condenses Water Temperature Regulation ON OFF 5 C 70 C 5 C with bimetallic capillary thermostat Nipple thread Gas cylindrical INSTALLATION BEFORE YOU START Check the pack to ensure you have all of the parts listed on pag 1 with no visible signs of damage If any of the part is missing ...

Page 6: ...THIS PRODUCT MUST BE EARTHED Don t use the MOBUS regulating box to lean the electrical towel rail on the floor as you can damage the plastic and water can penetrate inside with a risk of electrical shock The electrical heating element must be permanently connected to a suitable electricity supply by way of the cable provided This should be via a fused spur in accordance with the IEE Wiring Regulat...

Page 7: ...f necessary continue in order to have the regulating box facing forward Fig 6 6 Make sure that the MOBUS gasket is fully sealed to the female threadofthetowelrail Fig 4 7 Install properly the electrified towel rail with the MOBUS into the wall according totowel rail manufacturer instructions Makesure thatthetowel railhastheMOBUSbottomside 8 Verify that no water leakages occur and re tighten joints...

Page 8: ... threadofthetowelrailinthe oppositeverticaltubetowherethe3Bar valve isinstalled 7 Thenusinga27mmspannerturntheT piecewithscrewedMOBUS heatingelement untilthelastnipplethreadturnandifnecessary continue in order to have the regulatingbox facingforward Fig 10 8 Make sure that the MOBUS gasket is fully sealed to the female thread of thetowelrail 9 Install properly the electrified towel rail with the M...

Page 9: ... rail from the wall and reverseit carefully leaningit on asoft cloth surface 3 Using a 27 mm spanner unscrew the MOBUS rotating it anticlockwise until the MOBUS thread is completely off from towel rail GAS female thread Fig 14 4 Remove the MOBUS from the towel rail DUAL FUELINSTALLATION CENTRAL HEATINGANDMOBUS 1 Disconnect thecable from themains power 2 Closebothrailvalves removethewaterfromthetow...

Page 10: ...tion never switch the MOBUS ON to verify heating effectiveness DANGEROUSCONDITIONANDRISKS Duringinstallation de installationandmaintenance ensure workingplacesafetyuntiltheoperationiscompleted Don t use excessive force to turn the knob as you risk to break it In case of anomalous or strange working condition or if MOBUS has visible signs of damage disconnect the MOBUSand send it to the seller for ...

Page 11: ...y as it has no spare parts IMPORTANT In case of doubts please contact the Seller or refer to Contacts section IMPORTANT Please retain these instructions for future reference NOTESFORDISPOSALOFTHISPRODUCTVALIDFORTHEEUROPEANUNION The crossed out wheeled bin symbol on your product reminds you that in the European Union all electrical and electronic products and batteries must be taken to separate col...

Page 12: ...eutral and Ground wires Class 1 or connecting the Live Neutral and Fil Pilote control connection auxiliary wires Class 2 Live Neutral Ground Fil Pilote Class I Brown Blue Yellow Green Class 2 Brown Grey Black INSTALLATION CLASS I Cable and Wall 1 Insert resistance in the upside down radiator 2 Screw in the resistance using 25 mm wrench not included 3 Insert the cable into the grommet Connect the w...

Page 13: ...vom Heizkörper mit Kabel eventuell in der Wohnung installiert Setpoint Temperatur die erreicht u o beibehalten werden soll DISPLAY und BEDIENELEMENTE Display Taste Mode Taste Standby LED Das Gerät Stone kann mit den beiden Tasten bedient werden die sich am Gerät befinden oder mit der App die aus dem Store heruntergeladen werden kann STROMVERSORGUNG Für den Gebrauch kann das Gerät Stone mit dem Mitt...