C. TROUBLESHOOTING CHART 

 
 

 
 
 

D

RECOMMENDED SPARE PARTS

: To minimize downtime on this Rethermalizer upon a failure, at least 

one (1) of the following items should be kept in stock as a spare part in the local area: 

PROBLEM 

PROBLEM CAUSE 

CORRECTIVE ACTION 

Water will 
not flow into 
Rethermal-
izer Tub 

A.  Water shut-off valve in the closed position. 
B.  Electrical plug not connected to electrical 

receptacle. 

C.  ON/OFF switch in the OFF position. 
D.  Circuit breaker in the main electrical panel 

tripped. 

E.  Defective ON/OFF switch. 
F.  Defective water float liquid level switch. 
G.  Defective water solenoid valve.  
 

A.  Place shut-off valve in the open position. 
B.  Connect plug to receptacle. 
C.  Place switch in the ON position. 
D.  Reset circuit breaker and check for cause that 

made breaker trip. 

E.  Replace Toggle ON/OFF switch. 
F.  Replace water float liquid level switch. 
G.  Replace water solenoid valve. 
 
 

Water fills 
to the float 
level but is 
not heated. 

A.  Defective control relay. 
B.  Defective Thermostat. 
C.  Defective heat element contactor. 
D.  Defective heat elements.  
 
 

A.  Replace control relay. 
B.  Replace Thermostat. 
C.  Replace heat element contactor. 
D.  Replace heat element. 
 
 

GREEN fill 
lamp lights 
but there is 
no water 
flow. 

A.  Water shut-off valve closed. 
B.  Defective water float liquid level switch 
C.  Defective water solenoid valve. 
 
 

A.  Turn valve to open position. 
B.  Replace water float liquid level switch. 
C.  Replace water solenoid valve. 
 
 

30A243 

RECOMMENDED SPARE PARTS 

ULTRATHERM 3 MODEL REO-1620 RETHERMALIZER

 

DESCRIPTION 

PART NUMBER 

Liquid Level Float Switch 

18A004 

240 Control Relay

 

60A014 

230 SPST Water Solenoid Valve 

24348 

230V Contactor , Mechanical 3 Pole 

18A106 

30 AMP, 120-277 VAC 2 Pole 

60 F (16 C) to 250 F 

˚

˚

˚

(121 C) Thermostat

˚

 

22A148 

19 

Summary of Contents for REO-1620

Page 1: ...MODEL REO 1620 ELECTRIC ULTRATHERM 3 CE RETHERMALIZER 30A243 OPERATIONS MANUAL 302 Spencer Lane P O Box 5369 San Antonio Texas 78201 800 525 8130 210 731 5000 Fax 210 731 5099 www ultrafryer com...

Page 2: ...loyees who will operate and maintain the Electric Ultratherm 3 Rethermalizer Proper use of this manual will allow store employees to properly operate clean and maintain this equipment which will reduc...

Page 3: ...N UNAUTHORIZED SERVICE CENTER The electrical power supply for this appliance must be the same as indicated on the rating and serial number plate located on the outside of the rethermalizer door All wi...

Page 4: ...n relief is provided with the Rethermalizer Prior to movement testing maintenance and any repair on your Rethermalizer disconnect all electrical power 30A243 April 2013 4 This appliance is not intende...

Page 5: ...med by qualified certified licensed and or authorized installation or service personnel Qualified personnel must be experienced in such work be familiar with all electrical precautions involved and ha...

Page 6: ...stallation 11 CLEANING Initial 13 Daily 13 Weekly 13 RETHERMALIZER OPERATION General 15 Cooking 16 PREVENATIVE MAINTENANCE TROUBLESHOOTING CHART Preventative Maintenance 18 Troubleshooting Chart 19 Re...

Page 7: ...30A243 GENERAL INFORMATION 7...

Page 8: ...337 Mail order to Greenfield World Trade U S Office 3355 Enterprise Ave Suite 160 Ft Lauderdale FL 33331 Website www Greenfieldworld com 2 DAMAGES Ultrafryer Systems is not responsible for damage occu...

Page 9: ...inless steel with a 3 finish and is built as a table model The Model REO 1620 Electric Ultratherm 3 Rethermalizer is equipped with a Thermostat twin stainless steel chub baskets self filling water flo...

Page 10: ...30A243 INSTALLATION 10...

Page 11: ...er and or des caler 3 Have a licensed electrician perform the following a Connect an CE approved 3 wire electrical cord to the terminals inside the units electrical box shown to the right b Install an...

Page 12: ...CLEANING 30A243 12...

Page 13: ...rform the following routines at store closing 1 Allow ALL metal surfaces and the water to COOL remove the electrical plug from the electrical receptacle and CAREFULLY drain the water from the Rether m...

Page 14: ...RETHERMALIZER OPERATION 14...

Page 15: ...the Rethermalizer tub from 60 F 16 C to 212 F 100 C The recommended COOK temperature is 180 F 82 C and the suggested HOLD temperature is 180 F 82 C The Thermostat is located on the backside of the fr...

Page 16: ...4 When the RED heat ele ment indicator lamp turns OFF indication the water is at the desired HOLD tem perature 1 place the prod uct to be cooked into the appropriately NUMBERED section of the Chub Bas...

Page 17: ...30A243 PREVENTIVE MAINTENANCE TROUBLESHOOTING CHART 17...

Page 18: ...ide many years of trouble free service B INSPECTION REQUIREMENTS ITEM DAILY WEEKLY MONTHLY CORRECTIVE ACTION Electrical Plug Cord and Toggle ON OFF Switch X Inspect the Electrical Cord Plug and the To...

Page 19: ...de breaker trip E Replace Toggle ON OFF switch F Replace water float liquid level switch G Replace water solenoid valve Water fills to the float level but is not heated A Defective control relay B Def...

Page 20: ...PARTS INDENTIFICATION 30A243 20...

Page 21: ...mber i e 1 2 etc then obtain the part number and description for that index number on the page facing the sketches Use that part number and description when ordering a replacement part MODEL REO 1620...

Page 22: ...6B 6A 18 3 30A243 22...

Page 23: ...ch 19B781 11 Adjustable S S Bullet Feet 22022 12 30 Amp 120 277 VAC 2 Pole 60 F 16 C to 250 F 121 C Thermostat 22A148 13 Electrical Terminal Block 23015 14 240 Volt 3 Watt Snaplight w Red Lens 60059 1...

Page 24: ...30A243 WIRING DIAGRAMS 24...

Page 25: ...30A243 WIRING DIAGRAM Since minor wiring changes may occur in the future USE the diagram pasted to the Rethermalizer for circuit tracing and or troubleshooting the Rethermalizer 25...

Page 26: ...THIS PAGE INTENTIONALLY BLANK 30A243 26...

Reviews: