IMPORTANT SAFETY INFORMATION

Do not attempt to operate the oven until connection of 
utility service has been fully inspected by an authorized 
service technician or a Star Service Representative.  
This  service  is  required  by  Star  in  order  to  assist 
the purchaser in proper start-up of the oven on site.  

Please note the specific details on the Warranty and 

make certain that service connections are made to 
proper utility services.
The  warranty  shall  not  apply  if  the  oven  is  started 
up and operated prior to the utilities and oven being 
inspected and check-out made by an authorized service 

technician or a Star Service Representative. 

 

 

 

 

CAUTION

IMPROPER  INSTALLATION,  ADJUSTMENT, 
ALTERATION, SERVICE, OR MAINTENANCE 
CAN CAUSE PROPERTY DAMAGE, INJURY, 
OR  DEATH.    READ  ALL  INSTRUCTIONS 
THOROUGHLY  BEFORE  INSTALLING  OR 
SERVICING THIS EQUIPMENT.

 

 

CAUTION

Post  in  a  prominent  location  the  emergency 
telephone number of your local gas supplier and 
instructions to be followed in the event you smell 
gas.  If the smell of gas is detected, immediately 
call the emergency phone number of your local gas 
company.  They will have personnel and provisions 
available to correct the problem.

 

 

CAUTION

It  is  required  that  the  oven  be  placed  under  a 
ventilation hood to provide for adequate air supply 
and ventilation.

 

 

CAUTION

Minimum  clearances  must  be  maintained  from 
all  walls  and  combustible  materials.    Minimum 
clearances for this unit should be 0 inches from 
the rear (rear bumpers provided must be in place) 
and 6 inches from both sides.  Keep the oven free 
and clear of all combustible material.

 

 

CAUTION

Adequate  clearance  for  air  openings  to  the 
combustion control chamber on the right side 
of the oven is required.  Do not obstruct the 
ventilation holes in the control panels as these 
provide the combustion air for the burner and 
cooling air for the controls.

 

 

CAUTION

The oven is to be operated only on the type of 

gas and electricity shown on the specification 

plate.  The burner will not operate and gas will 

not flow through the burner without electric 

power.

INSTALLATION INFORMATION

T H E   I N S TA L L AT I O N   I N S T R U C T I O N S 
CONTAINED HEREIN ARE FOR THE USE OF 
QUALIFIED  INSTALLATION  AND  SERVICE 
PERSONNEL  ONLY.    INSTALLATION  OR 
SERVICE  BY  OTHER  THAN  QUALIFIED 
PERSONNEL  MAY  RESULT  IN  DAMAGE 
TO  THE  OVEN  AND/OR  INJURY  TO  THE 
OPERATOR.

Qualified  installation  personnel  are  individuals,  a 

firm,  a  corporation,  or  a  company  which  either  in 

person or through a representative are engaged in 
and responsible for:
1.  The installation or replacement of gas piping and 

the connection, installation, repair, or servicing of 
equipment.

2.  The installation of electrical wiring from the electric 

meter, main control box, or service outlet to the 
electric appliance.

Qualified installation personnel must be experienced 

in such work, familiar with all precautions required, 
and have complied with all requirements of state or 
local authorities having jurisdiction.

5

Summary of Contents for UM1854-NATX

Page 1: ...GAS CONVEYOR OVEN MODEL UM1854 NATX UM1854 LPX Installation and Operation Instructions 2M Z6535 Rev H 5 23 08 UM1854...

Page 2: ...nges in designs methods procedures policies and regulations the speci cations contained in this sheet are subject to change without notice While Star Manufacturing exercises good faith efforts to prov...

Page 3: ...Separate 10 Amp 230VAC single phase 50 60 Hz service per Oven Approximate Weight Single Oven with Cart Installed 280 Lbs 127 27 kg Shipping 350 Lbs 159 09 kg Dimensions Width 60 6 153 9 cm Depth 39 9...

Page 4: ...NOTICE This appliance must be installed with a stand and casters designed by Star Manufacturing as part of a completeinstallation Theinstallationmustalsoinclude aconnectorcomplyingwitheitherANSIZ21 6...

Page 5: ...ustible materials Minimum clearances for this unit should be 0 inches from the rear rear bumpers provided must be in place and 6 inches from both sides Keep the oven free and clear of all combustible...

Page 6: ...f improper ventilation will not be covered by the warranty VENTILATION AVENTISREQUIRED Localcodesprevail These are the authority having jurisdiction as stated by the National Fire Protection Associati...

Page 7: ...DERATIONS Locating the gas valve s quick connect hose s and electrical outlet s at the control box end of the oven will allow easier access for any service visits This improved access should make any...

Page 8: ...of thegassupplypipingsystemattestpressures equal to or less than 1 2 psig 3 45 kPa 3 Ifincomingpressureisover14 watercolumn a separate regulator for the oven must be installed before the gas supply t...

Page 9: ...becomes effective upon verification of proper installation CAUTION DO NOT WORK AROUND THE CONVEYOR BELT WITH LONG HAIR LOOSE CLOTHING OR DANGLING JEWELRY GETTING CAUGHT IN THE BELT COULD RESULT IN DI...

Page 10: ...light any appliance 2 DO NOT touch any electrical switches 3 Use an exterior phone to call your gas supplier immediately 4 If you cannot reach your gas supplier call the fire department In the event...

Page 11: ...r an additional 4 seconds The TEMP display shows LOC as the TIME display shows nO which indicates that the TIME TEMP parameters can be changed after reaching the STORE level yES indicates thattheparam...

Page 12: ...ake has been established the fine adjustments should be made by holding either the bake time or bake temperature constant then varying the other CONVEYOR SPEED Bake Time Conveyor Speed As stated previ...

Page 13: ...andards CAUTION If the gas oven needs to be moved the gas mustbeturnedoffanddisconnectedfromthe unit before moving the restraint Reconnect the restraint after the oven has been returned to its origina...

Page 14: ...ete or the small handle left canbeusedtoslide nozzle and columnating plate out before removing the main body 7 The lower finger assembly can be removed complete or the nozzle can be slid off to reveal...

Page 15: ...er continuous use Following are the necessary steps for removing links 1 Move the splice clips to either end of the oven for easy access 2 Unhook the splice clips using long nose pliers 3 Unhook the f...

Page 16: ...BRN BLU 7 6 DS 2 S1 8 30 15 2 5 1 4 34 23 26 37 26 37 TB 4 _ 8 9 5 36 10 _ 21 41 21 19 _ _ _ 30 BLU 15 9 32 35 24 SV DV GRN 3 FS SE 33 38 25 40 17 38 24 16 35 PLUG ON BACK OF MOTOR IS SHOWN ROTATED 1...

Page 17: ...H TO 230V BEFORE INSTALLING 14 4 T C PR 10 14 H C NO NC L DS B CN3 TO MOTOR 6 COM 5 ENABLE 4 DIR 3 SPEED 2 COM 1 TACH 1 CN3 CN5 TO SMALL MOTOR 7 SPEED GRD 6 SPEED SIGNAL 5 SPEED 5V REF 4 NOT USED 3 TA...

Page 18: ...cleaners This warranty does not apply to the non stick properties of such materials This warranty is not valid on Conveyor Ovens unless a start up check out has been performed by a Factory Authorized...

Page 19: ...ACTURING INTERNATIONAL INC MODEL UM1854 SK1905 REV B 2 7 06 CONTROL BOX ASSEMBLY SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES ONLY AND IN CERTAIN INSTANCES MAY NOT BE AVAILABLE THIS DRAWING CONTA...

Page 20: ...MER 16 2E Z5163 1 IGNITION CONTROL 17 G9 Z5661 1 ELECTRODE SET 18 2U Z5171 1 GEARMOTOR 500 1 24V DC 2U Z8629 1 GEARMOTOR 240 1 230VAC 19 2A Z6534 1 COUPLING 20 2F Z5173 1 BURNER NATURAL 2F Z5660 1 BUR...

Page 21: ...goes blank 3 Press the up button to increase or the down button to decrease TIME or TEMPERATURE Hold button down for switch to the OFF position and wait five minutes To Start Push power switch ON Afte...

Page 22: ...16 G9 GC0040 1 FAN INLET PLATE 17 G9 Z5338 1 FAN INLET BELL 18 2A Z5551 4 FAN INLET SPACER 19 G9 Z5549 2 REAR BUMPER 20 G9 GC0041 1 REAR COVER 21 PS Z8749 1 BLOWER MOTOR HEAT SHIELD KIT 115V PS Z8750...

Page 23: ...IN CERTAIN INSTANCES MAY NOT BE AVAILABLE THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MANUFACTURING INTERNATIONAL INC NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED STAR MANUFA...

Page 24: ...cription Star Manufacturing International Inc MODEL Part Number Key Number 1 G9 Z5516 1 LOWER FINGER BAFFLE 2 G9 GC0037 1 LOWER FINGER DIVERTER ASSEMBLY 3 G9 GC0035 1 LOWER FINGER WELDMENT 4 G9 GC0043...

Page 25: ...1 D placezles pissureattaches n importequelle extr mit du four pour l acc s facile 2 D crochez les pissure attaches en utilisant de longues nez pinces 3 D crochez le plein lien enlever et glissez le d...

Page 26: ...e complet enlev ou la petite poign e gauche peut tre utilis e pour glisser le bec et le plat columnating dehors avant d enlever le corps principal 7 Le doigt inf rieur peut tre enlev complet ou le bec...

Page 27: ...gaz doit tre d plac le gaz doit tre arr t et d mont partir de l unit avant de d placer la contrainte Rebranchez la contrainte apr s que le four ait t retourn son endroit original Suivez ces recommand...

Page 28: ...uence un produit br l 4 Une fois un bon cuisinier a t tabli les ajustements fins devrait tre fait en jugeant le temps de cuisinier ou la constante de la temp rature de cuisinier changeant alors l autr...

Page 29: ...e de la TEMP RATURE montre LOC pendant que l affichage de TEMPS montre nO ce qui indique que les param tres de TEMPS TEMP RATURE peuvent tre chang s apr satteinte du Stockez de Niveau yES indique que...

Page 30: ...LEVEZ la fl che pour augmenter ou DUNElafl che pourdiminuerleTEMPSoula TEMP RATURE Maintenezl unoul autrebouton pour des changements plus rapides d affichage 4 Apr s cinq en second lieu les nouveaux...

Page 31: ...l installation appropri e ATTENTION NE TRAVAILLEZ PAS AUTOUR DE LA BANDE DE CONVEYEUR AVEC DE LONGS CHEVEUX HABILLEMENT L CHE OU BIJOUXBALAN ANTS SEFAIREATTRAPER DANS LA CEINTURE A PU AVOIR COMME CON...

Page 32: ...de gaz la pression d essai gale ou au moins de 1 2 psig kPa 3 45 3 Si la pression entrante est plus de colonne de l eau de 14 un r gulateur s par pour le four doit tre install avant la fourniture de...

Page 33: ...cette unit v rifiez que l alimentation d nergie est proportionn e pour la tension l amp rage et les conditionsdephaseindiqu esdelaplaquedecontr le Un diagramme de c blage est inclus sous ce pli 8 Une...

Page 34: ...efficacit de diverses conceptions de capot le rend n cessaire d indiquer un ventail si du ventilateur CFM De l air de maquillage doit par tre fourni une conception de capot ou le syst me de HVAC pour...

Page 35: ...compli dans le mouvement limit fourni par la contrainte de tuyau de gaz Si le four doit tre d plac plus loin du mur le gaz doit d abord tre arr t et d mont du four avant d enleverlacontrainte Rebranch...

Page 36: ...INSTALLATION INEXACTE L AJUSTE MENT LE CHANGEMENT LE SERVICE OU L ENTRETIEN PEUVENT CAUSER DES D GATS MAT RIELS DES DOMMAGES OU LAMORT LISEZTOUTESLESINSTRUCTIONS COMPL TEMENT AVANT D INSTALLER OU ENTR...

Page 37: ...PAS ESSENCE OU AUTRES VAPEURS ET LIQUIDES INFLAMMABLES PROXIMIT DE CECI OU AUCUN AUTRE APPAREIL L installation de l appareil doit se conformer au ANSI Z223 1 LATEST EDITION et TOUS LES R GLES ET R GLE...

Page 38: ...monophas 50 60 Hz service par Four Poids Approximatif Un Four avec le Chariot Install 280 Lbs 127 27 kg Transport 350 Lbs 159 09 kg Dimensions Largeur 60 6 153 9 cm Profondeur 39 9 99 82 cm La porte...

Page 39: ...uits sans communication pr alable De telles r visions ne ont pas droit l acheteur aux changements aux am liorations aux additions ou aux remplacements correspondants pour l quipement pr c demment ache...

Page 40: ...FOUR de CONVOYEUR de GAZ MOD LES UM1854 NATX UM1854 LPX Instructions d installation et d op ration 2M Z56535 Rev G 5 23 08 UM1854...

Reviews: