The UltimateAir® RecoupAerator® 200DX Manual and Installation Guide, March 2014
5.
After stripping 1/4" of insulation from each of the wire ends, complete
the wiring by matching each labeled between the 3-Motor Main Control
and the Wall Dial. Be sure all connections are secure by lightly pulling
each wire.
6.
If wiring to a furnace, you MUST REMOVE jumpers JP6 and JP7. If NOT
wiring to a furnace, jumpers JP6 and JP7 MUST be in place. See furnace
wiring for more detail in this manual.