【 Standard specifications 】
Items
Specifications
Measurement
Type
Ratemeter/Totalizer
Method
Cycle calculation method
Display
Display
Red LED : 5 digits, Character height : 7mm(range : 0 - 99999)
Display switching
Rate meter/Totalizer
Rate
meter
Display accuracy
±0.05%rdg.±1digit
( at Sampling time for 0.5 second or more )
Scaling
1×10
-9
- 9999(per pulse)
Indication area
0 – 99999
Overflow indication "99999" flashing, endless, or 10x shift.
Time unit
10
-1
, 10
-2
, 10
-3
, 10
-4
, nothing
Sampling time
Rate reading averaged by 0.1-100.0 sec.
Moving average
Display moving average.
Averaged by 2 to 19 indication values.
Pulses moving average
Averaged by 2 to 19 input pulses.
Auto zero time
After an input signal is stopped, the reading turns to zero after
time that can be set 0.1 – 99.9 sec.
Least significant digit Real, fixed at 0, or 0/5
Totalizer
Measurement
accuracy
±0 (Scaling is set to 1.)
Scaling
1×10
-9
- 9999(per pulse)
Indication area
0 – 99999
Decimal point
10
-1
,10
-2
,10
-3
,10
-4
,nothing
Overflow Indication "99999" flashing, endless, or 10x shift.
Offset
Value after a reset at the reach of 0 - 99999. (selectable)
Sensor
input
Input signal
NPN open collector pulse input or No-voltage contact.
*Sensor conditions:
ON residual voltage 2.0V or less, OFF leakage current 1.5mA or less.
Can open and close load current of 10.0mA.
Input response frequency
(at 50% duty)
LO : 0.01Hz - 50Hz
HI : 0.01Hz - 10kHz
Sensor power
DC 12V(±10%) 50mA (max.)
EXT
input
Input method
NPN open collector input or No-voltage contact. (×1)
* It works by turning it ON for 50ms or more.
Function selection Reset / Hold / Inhibit / Indication change
Synchronize
totalizer of
pulse output
Output method
NPN open collector output. (×1)
* It's impossible to use at the time of P1 option choice.
Maximum rating
DC30V 50mA.(max)
Output digits
1 - 4 digits.
Output width
0.01 - 1.99 sec.
* Maximum output frequency is 50Hz.