- 29 -
Mode No. Totalizer : Setting of the synchronization pulse output
b
※ Not displayed when P1 option is selected
! < Caution >
* It will function, if the totalizer synchronous pulse output is
set up by output selection of the mode No.9.
The synchronization pulse is outputted from OUT1
(terminals no. 3-4).
A B C D E
b. 0 0.0 5
Synchronization pulse output width setting
0.01-1.99 sec. ("00.0" is "0.01 sec".)
Output digit selection
0 : 1st digit (E)
1 : 2nd digit (D)
2 : 3rd digit (C)
3 : 4th digit (B)
【 Output digit 】
The digit whose change is to trigger the pulse output is specified.
【 Pulse output width 】
The output width of synchronization pulse is specified.
! < Caution >
* Caution is required as the synchronization output pulse is
renewed each time the output digit value changes : if the
pulse width is set longer than the time interval of the output
digit change, the pulse output becomes continuous.
! < Caution >
* When 0.01 sec. were set by a synchronization pulse output,
an output response is faster than indication scan,
so "OUT1 LED" sometimes doesn't light up.
It's outputting.