12. Calling up and modifying the offset value setting
The preset totalizer reading value to be displayed directly following a reset is
specified.
For example, if the offset value is set at "01000", the reading becomes "1000"
when reset, and the count resumes from "1000".
In order to start the count from "0", the offset value should be set as "00000".
The possible range for offset is 0-99999.
The procedure for setting the offset value is described below.
≪Operation of the offset value setting≫
* When there are no customer requests,the initial value setting is "00000".
Operation key
Indication
Procedure
+
A B C D E
1○
2○ 0 0 0 0 0
T●
While pushing down Mode Key, press
Display Key for 2 sec. or more.
"T" LED lights up and the present offset
value is displayed.
A B C D E
1○
2○
0
→0→0→0→0
T● └---←---┘
Shifts the flashing indication to the digit to
the right.
Each time Shift Key is pressed, shifts the
indication to one right.
A B C D E
1○
2○ 0
1
0 0 0
T●
Changes the value of the flashing digit.
Each time Display Key is pressed, the number
goes up by one.
(0→1→……→9→0→……)
A B C D E
1○
2○ Measured value
T●
After adjusting the setting, use Reset Key to
register it.
The display returns to the readings following
registration.
≪After registration≫
A B C D E
1○
2○ 1 0 0 0
T●
The registered offset value can be displayed
by pressing Reset Key.
The totalizer count is resumed from this
value.
! < Caution >
※The mode protection function is invalid.
(Please refer to "11. The mode protect function".)
※The decimal point is interlocked with the mode No.8.
※When using "offset return" by mode No.A, please be sure to set the preset value
by the following condition.
Always reset before starting count.
"Preset value > Offset value"