background image

- 3 - 

Programming with DCC devices  

Use the programming menu in your DCC Centre, to program the decoder CV’s in either 
register, direct CV or page programming mode. It is also possible to program the decoder on 
the main line using a DCC Centre.  
Refer to the manual for your control centre for full instructions on the process. 

Programming of long Addresses without the Programming Menu  

For programming with a centre which does not support programming with an input menu, the 
value for CV17 and CV18 must be calculated. Here is an example for programming the address 
2000. 

 

Divide the addresses by 256 (2000:256 = 7 remainder 208).  

 

Take the result (7) and add it to 192.  

 

Program this value (199) into CV17.  

 

Program the remainder (208) into CV18.  

 

Important

: Set Bit 5 of CV 29 to 1, so the decoder uses the long address.  

Calculating the CV value  

With CV29 and CV49 various characteristics of the decoder be established.   

The required values are easily calculated using the CV table and simply addition.  

Example

:  

Normal travel direction 

Value = 0 

28 speed steps 

 

Value = 2 

Speed steps via CV 2, 5, 6 

Value = 0 

Short address 

 

Value = 0 

The total value is 2. 
This value is factory default for CV29. 

 

 

Table of individual CV's (Configuarion Variables)  

CV 

 

Description 

 

Value range 

 

Factory 

default

 

1  

Locomotive address 

DCC 1-127  

Mot 1-80  

SX: 1-111 

3  

Minimum speed value 

1-63 

3 Start 

Inertia 

1 means every 5ms the speed will be increased by 1 
Sets the internal maximum speed e.g. 200 (CV5=50 or 
CV94=200) then starts the locomotive from 0 to Fmax in 1sec 

1-63 2 

Braking inertia (time factor like CV3) 

1-63 

Maximum speed (must be lager than CV2) 

1-63 

48 

6 Middle 

speed 

1-63 

24 

7  

Software version (The processor used can be updated)  

8  

8  

Manufacturer ID  

85  

17,18 Long 

address 

1-9999 

2000 

17 

Long address high byte  

192-231  

199 

18 

Long address low byte 

0-255 

208 

19 Consist 

address 

(Multi-traction) 

0 = Consist address is inactive 
When Bit 7=1 the driving direction is reversed 
So the desired CADR + 128 = driving direction reversed 

1-127 0 

Bit

 

Function CV29

 

Value

 

Normal travel direction 
Reverse travel direction 


14/27 speed steps 
28/128 speed steps 


Speed steps in CV2, CV5 and CV6 
Characteristics read from CV67-94  

16 

Short address (CV1, Register 1) 
Long address (CV17 and CV18) 

32 

Summary of Contents for 73 510

Page 1: ... digital systems and also runs in DC analog mode The decoder operates with a frequency of 18 75KHz and is therefore well suited for DC and especially for Bell armature motors e g Faulhaber Maxon Escap up to a maximum power load of 500mA Short burst start up currents are tolerated Motor characteristics can be controlled either by setting the minimum maximum and middle speeds or via various CV s for...

Page 2: ...ctrix To read or program the Intellibox selected Selectrix data format a Selectrix controller or a Selectrix programming device can be used The data format of the decoder will automatically switch to Selectrix when CV49 bit 4 1 The decoder can then be operated in Selectrix mode Programming In factory default state all decoder options are changed using configuration variables CV s according to the ...

Page 3: ... speed steps Value 2 Speed steps via CV 2 5 6 Value 0 Short address Value 0 The total value is 2 This value is factory default for CV29 Table of individual CV s Configuarion Variables CV Description Value range Factory default 1 Locomotive address DCC 1 127 Mot 1 80 SX 1 111 3 2 Minimum speed value 1 63 1 3 Start Inertia 1 means every 5ms the speed will be increased by 1 Sets the internal maximum ...

Page 4: ... between analog and digital operation 0 Digital operation 1 Analog operation 0 1 0 52 Speed at the end of a braking section Relevant when CV49 Bit 2 1 and Bit 7 1 0 255 30 53 Repetition rate of load regulation CV49 Bit 0 1 Rate Value 53us 0 255 80 54 Load regulation increase motor voltage 0 255 2 55 Load regulation decrease motor voltage 0 255 2 56 AD transducer correction Do Not Change 0 255 1 57...

Page 5: ...ou enter the special programming mode by entering an address value of 0 and pulse width value of 4 Note Because address 0 is used to place the decoder into programming mode it cannot be used as a normal address Now tell the decoder which CV you wish to call up Look for particular values for Signal brake section BS Top Speed TS and Start brake inertia SB in the programming table and program the dec...

Page 6: ...3 1 83 2 7 5 20 1 7 3 52 2 4 1 84 2 1 6 21 1 1 4 53 2 5 1 85 2 2 6 22 1 2 4 54 2 6 1 86 2 3 6 23 1 3 4 55 2 7 1 87 2 4 6 24 1 4 4 56 2 1 2 88 2 5 6 25 1 5 4 57 2 2 2 89 2 6 6 26 1 6 4 58 2 3 2 90 2 7 6 27 1 7 4 59 2 4 2 91 2 1 7 28 1 1 5 60 2 5 2 92 2 2 7 29 1 2 5 61 2 6 2 93 2 3 7 30 1 3 5 62 2 7 2 94 2 4 7 31 1 4 5 63 2 1 3 95 2 5 7 32 1 5 5 64 2 2 3 96 2 6 7 Programming with a Märklin Centre Al...

Page 7: ... a value of 57 The decoder will calculate the CV value as 4 25 57 Following programming CV63 should be set back to zero so that following value smaller than 79 are not incorrectly programmed Technical Data Addresses 1 9999 long DCC Address Max Motor current 0 5A Function outputs 0 5A each Total Load 0 5A Size 8 6 x 12 0 x 3 7 mm The decoder is preset to address 03 operating with 28 speed steps 28 ...

Page 8: ... warranty claim is void if the damage was caused by inappropriate treatment Please note that according to EMV regulation the component may only be installed in vehicles which carry the CE logo Our contact Details Service In the event of a defect or failure send the unit together with the invoice and a short description of the fault back to us for repair Hotline We are available if you have any que...

Reviews: