background image

- 8 - 

www.uhlenbrock.de

 

Visit our website for up-to-date information about the Intellibox, a Price or Dealer list or to 
download various publications.  

Guarantee declaration 

Each component is tested for its complete functionality before distribution.  If a fault should arise 
within the guarantee period of 2 years, we will repair the component free of charge upon production of 
proof of purchase.  The warranty claim is void

if the damage was caused by inappropriate treatment.   

Please note that, according to EMV regulation the component may only be installed in vehicles

,

 which 

carry the CE logo. 

 
 

 

 

 

Our contact Details: 

Service 

In the event of a defect or failure send the unit together 

with the invoice and a short description of the fault back to 

us for repair. 

 

Hotline 

We are available if you have any questions! 

Your direct line to a technician: 

0 20 45 - 85 83 27 

Mon - Tue - Thu – Fri, 14:00~16:00 and Wed 16:00~18:00

 

Uhlenbrock Elektronik GmbH 
Mercatorstr. 6 
D-46244 Bottrop 
Made in Germany

  

 

Part No. 73 510

Summary of Contents for 73 510

Page 1: ... digital systems and also runs in DC analog mode The decoder operates with a frequency of 18 75KHz and is therefore well suited for DC and especially for Bell armature motors e g Faulhaber Maxon Escap up to a maximum power load of 500mA Short burst start up currents are tolerated Motor characteristics can be controlled either by setting the minimum maximum and middle speeds or via various CV s for...

Page 2: ...ctrix To read or program the Intellibox selected Selectrix data format a Selectrix controller or a Selectrix programming device can be used The data format of the decoder will automatically switch to Selectrix when CV49 bit 4 1 The decoder can then be operated in Selectrix mode Programming In factory default state all decoder options are changed using configuration variables CV s according to the ...

Page 3: ... speed steps Value 2 Speed steps via CV 2 5 6 Value 0 Short address Value 0 The total value is 2 This value is factory default for CV29 Table of individual CV s Configuarion Variables CV Description Value range Factory default 1 Locomotive address DCC 1 127 Mot 1 80 SX 1 111 3 2 Minimum speed value 1 63 1 3 Start Inertia 1 means every 5ms the speed will be increased by 1 Sets the internal maximum ...

Page 4: ... between analog and digital operation 0 Digital operation 1 Analog operation 0 1 0 52 Speed at the end of a braking section Relevant when CV49 Bit 2 1 and Bit 7 1 0 255 30 53 Repetition rate of load regulation CV49 Bit 0 1 Rate Value 53us 0 255 80 54 Load regulation increase motor voltage 0 255 2 55 Load regulation decrease motor voltage 0 255 2 56 AD transducer correction Do Not Change 0 255 1 57...

Page 5: ...ou enter the special programming mode by entering an address value of 0 and pulse width value of 4 Note Because address 0 is used to place the decoder into programming mode it cannot be used as a normal address Now tell the decoder which CV you wish to call up Look for particular values for Signal brake section BS Top Speed TS and Start brake inertia SB in the programming table and program the dec...

Page 6: ...3 1 83 2 7 5 20 1 7 3 52 2 4 1 84 2 1 6 21 1 1 4 53 2 5 1 85 2 2 6 22 1 2 4 54 2 6 1 86 2 3 6 23 1 3 4 55 2 7 1 87 2 4 6 24 1 4 4 56 2 1 2 88 2 5 6 25 1 5 4 57 2 2 2 89 2 6 6 26 1 6 4 58 2 3 2 90 2 7 6 27 1 7 4 59 2 4 2 91 2 1 7 28 1 1 5 60 2 5 2 92 2 2 7 29 1 2 5 61 2 6 2 93 2 3 7 30 1 3 5 62 2 7 2 94 2 4 7 31 1 4 5 63 2 1 3 95 2 5 7 32 1 5 5 64 2 2 3 96 2 6 7 Programming with a Märklin Centre Al...

Page 7: ... a value of 57 The decoder will calculate the CV value as 4 25 57 Following programming CV63 should be set back to zero so that following value smaller than 79 are not incorrectly programmed Technical Data Addresses 1 9999 long DCC Address Max Motor current 0 5A Function outputs 0 5A each Total Load 0 5A Size 8 6 x 12 0 x 3 7 mm The decoder is preset to address 03 operating with 28 speed steps 28 ...

Page 8: ... warranty claim is void if the damage was caused by inappropriate treatment Please note that according to EMV regulation the component may only be installed in vehicles which carry the CE logo Our contact Details Service In the event of a defect or failure send the unit together with the invoice and a short description of the fault back to us for repair Hotline We are available if you have any que...