background image

11 

Configuration of Servo outputs 

CV for servo output 

Factory defaults 

1 2 3 4 

Description Value 

Range 

1 2 3 4 

120 130 140 150 1. 

Address 

high 

byte 

0-8 

0  0  0  0 

121  131  141  151  1. Address low byte 

0-255 

1* 

3* 

5* 

7* 

122  132  142  152  Stop position “red” Address 1 

0-127 

30 

30  30

30

123  133  143  153  Stop position “green” Address 1 

0-127 

95 

95  95

95

124 134 144 154 Switchover 

time 

0-255  40  40  40

40

125  135  145  155  Relay Switching point setting “red” 

0-2 

126  136  146  156  Relay Switching point setting “green” 

0-2 

160 170 180 190 2. 

Address 

high 

byte 

0-8 

0  0  0  0 

161  171  181  191  2. Address low byte 

0-255 

162  172  182  192  Stop position “red” Address 2 

0-127 

163  173  183  193  Stop position “green” Address 2 

0-127 

*) When a Motorola center is used the factory  programmed addresses are not usable and must be adjusted by the 

user via key programming. 

Guarantee declaration 

Each component is tested for its complete functionality before distribution.  If a fault 
should arise within the guarantee period of 2 years, we will repair the component 
free of charge upon production of proof of purchase.  The warranty claim is void if 
the damage was caused by inappropriate treatment.   

The trade names mentioned are registered trade marks of the respective companies. 

 

 

 

02045 

8583-27

 

If you have any questions call us. Hotline times are: 
Mon - Tue - Thu - Fri, 14:00-16:00 and Wednesdays 16:00-18:00

 

 

Our products are covered by a two year warrantee.  If it is defective send decoder along 

with the receipt of purchase to the following address: 

Uhlenbrock Elektronik GmbH * Mercatorstr. 6 * 46244 Bottrop 

Tel: 02045-8583-0 * Fax: 02045-8684-0  * www.uhlenbrock.de

 

Summary of Contents for 67810

Page 1: ...x Configured by digital system s turnout keys x Or by DCC CV Programming x Power supplied from the track or a separate transformer x Very low power consumption by use of an integrated regulator x All...

Page 2: ...ntly The speed at which the servo moves between the two end positions can also be configured For special applications each of the connected servos can be stopped at two additional stops by an addition...

Page 3: ...teristic and is not produced by the servo decoder we recommend to connect the Trafo terminals to a 16V model railway transformer This will ensure that the uncontrolled movements of the Servos will onl...

Page 4: ...ramming by Key and Solenoid Command The desired servos should be connected to the outputs that are to be programmed and should be attached since the servo decoder acknowledges the setting of the servo...

Page 5: ...rvo output On the digital center or another control device which can switch solenoids operate one of the two keys red or green which are to move this servo later The servo decoder acknowledges the key...

Page 6: ...The servo now moves independently back and forth with the set speed between the two stop positions The speed of the movement can be increased or decreased with the and keys as specified in step 5 8 T...

Page 7: ...servo operation and if the operating mode is Motorola or DCC The entered value is calculated from the CV table in which the values of the desired functions are added Example Output 1 power always on...

Page 8: ...120 remains at value 0 factory setting Addresses from 256 values for the High byte and the Low byte must be calculated For example programming of the address 2000 is as follows x Divide the address va...

Page 9: ...end position 2 switching point time at the servo green end position CV125 135 145 155 Switching point time with switching command red for outputs 1 4 CV126 136 146 156 Switching point time with switc...

Page 10: ...iption Value Range Factory Default 112 Software version the processor used can be updated varies 113 Manufacturer code 85 119 Decoder Configuration Power output 1 Bit 0 0 only on during servo movement...

Page 11: ...27 0 0 0 0 When a Motorola center is used the factory programmed addresses are not usable and must be adjusted by the user via key programming Guarantee declaration Each component is tested for its co...

Reviews: