AeroCut nano+ SERVICE MANUAL
30
6- (8) PCB (CPU board) setting
TP7
TP6
Set a multi-meter
to DC.
Adjust VR2 to
0.310V while in
operation
and adjust VR1 to
0.100V while not
in operation.
All switch to left
Switch only No.2
to right
Double feed
detection sensor.
VR7 must be fully
turned
counterclockwise.
VR5 does not
require any
adjustment.
VR6 to adjust the
sensitivity that
can be referred in
service mode.
VR4
VR3
VR1
VR2
VR7
VR6