9
www.ubisys.de
u
subsequent press (within half a second) increments the option number. Once the desired option is reached,
wait for the LED to blink the selected number of times. Then, press a single time to accept the selection or
wait for three seconds to cancel the command. The LED will blink one time to confirm an affirmative choice,
or two times to indicate the request has been cancelled. The following options are available:
Option #1: Join an existing ZigBee network as router
Option #2: Form a new distributed security network as the first router
Option #3: Form a new centralized security network as the coordinator and trust center
5
Factory Reset
Put the device into the same state as it was when it left the factory, then reboot. The only exception is the
outgoing network security frame counter, which is preserved across factory resets. The device will
broadcast a network leave indication.
6
6
ZigBee Commissioning: Advanced Commands
Provides a number of advanced ZigBee commissioning command options. Select this menu item and leave
menu mode. Afterwards the device expects the selection of an option. The first button press starts the
selection of the option and each subsequent press (within half a second) increments the option number.
Once the desired option is reached, wait for the LED to blink the selected number of times. Then, press a
single time to accept the selection or wait for three seconds to cancel the command. The LED will blink one
time to confirm an affirmative choice, or two times to indicate the request has been cancelled. The following
options are available:
Option #1: Perform a simple reset (reboot), then continue operating seamlessly (silent re-join)
Option #2: Perform a simple reset (reboot), then re-join the network
Option #3: Perform a full factory reset, including security frame counters and preserved settings
7
Reserved for internal use. Do not leave the menu in this mode.
6.1.
Power-Cycle Sequencing Factory Reset
It is possible to instigate a factory reset using a special power-cycle sequence
7
. This is equivalent to
selecting menu item #5, with the advantage that you need no access to the device itself (only to its
power supply).
1.
Power the device for at least four seconds.
2.
Interrupt the power supply for at least a second.
3.
Reapply power for less than two seconds but more than half a second.
Notice that at the end of this cycle, the device is off and should remain off for at least a second.
4.
Repeat the previous step two more times, for a total of three short power cycles.
5.
Apply power to the device and leave it powered on.
The device will now factory reset and reboot.
6
Since application firmware 1.05. Previously, the factory reset would result in a silent leave.
7
Since application firmware 1.08