7.5.4.
On/off Cluster (Client)
Notice: This cluster uses the binding table for managing command targets. When factory fresh, this
cluster is bound to endpoint #2 to enable local control. This works even when the device is not
commissioned yet. In addition, the device setup cluster on the Device Management endpoint can be
used to configure the behavior of the cluster, i.e. which of the commands mentioned below will actually
be sent, when the input state changes. Using the device setup cluster, you can configure this endpoint
either to be used with a push-button (momentary switch, one stable position) or a rocker switch (two
stable positions).
Cluster commands transmitted:
Command
Description
0x00
Turn off
Turns the target device or group of devices off.
0x01
Turn on
Turns the target device or group of devices on.
0x02
Toggle
Toggles the target device state. Should not be used to control groups.
7.5.5.
Level Control Cluster (Client)
Notice: This cluster uses the binding table for managing command targets. In addition, the device setup
cluster on the Device Management endpoint can be used to configure the behavior of the cluster, i.e.
which of the commands mentioned below will actually be sent, when the input state changes. Using the
device setup cluster, you can configure this endpoint either to be used with one or two push-buttons.
This cluster instance is intended for controlling remote dimmers using the local inputs and is not bound
when factory fresh.
Cluster commands transmitted:
Command
Description
0x05
Move with on/off
Moves the level either up or down at a specified rate.
Maintains the companion on/off cluster’s OnOff attribute.
0x07
Stop with on/off
Stops any level change in progress due to a move, move to level, step or recall scene command.
Maintains the companion on/off cluster’s OnOff attribute.