17
www.ubisys.de
u
7.3.
Application Endpoint #2 – On/off Output #2
Use this application endpoint to control the load output, which is marked with a wave crossed by an
arrow, tagged with a “2”. In case of S2, this is the black wire.
This is a Finding & Binding target endpoint.
The application endpoint exposes the following clusters:
Cluster
Direction
Description
0x0000
Inbound
(Server)
Basic
Provides basic information about the device, such as the manufacturer ID, vendor and model
name, stack profile, ZCL version, production date, hardware revision etc. Allows a factory reset
of attributes, without the device leaving the network.
0x0003
Inbound
(Server)
Identify
Allows to put the endpoint into identify mode. Useful for identifying/locating devices and
required for Finding & Binding.
0x0004
Inbound
(Server)
Groups
Allows adding this endpoint to one or more groups. Afterwards the endpoint can be addressed
using the group address. This is also a prerequisite for scenes. You may also query group
membership and delete group associations.
0x0005
Inbound
(Server)
Scenes
Allows storing one or more scenes per group, where each scene consists of a pre-set on/off
state value. You may either store the current values as a scene, or provide scene settings when
adding a scene, or delete scenes.
0x0006
Inbound
(Server)
On/off
Provides control of the output #2 (black wire on S2)
7.3.1.
Basic Cluster (Server)
Please refer to section 7.7.1 for details.
7.3.2.
Identify Cluster (Server)
In identify mode, the output relay will be toggled once every second.
Caution: Make sure the attached load can handle this switching rate or physically disconnect the load!
Attributes supported:
Attribute
Type
Description
0x0000
unsigned16
IdentifyTime
The remaining time, in seconds, the device will be identifying itself.
Notice that S2 currently does not provide any visual feedback in identify mode.
Cluster commands supported:
Command
Description
0x00
Identify
Puts the device into identify mode, or terminates identify mode.