![Ubisys ZIGBEE S2(-R) Reference Manual Download Page 35](http://html1.mh-extra.com/html/ubisys/zigbee-s2-r/zigbee-s2-r_reference-manual_3156323035.webp)
35
www.ubisys.de
u
In addition, any Green Power device that sends at least one of the supported commands listed in the
next section can also be paired with the dimmer.
Supported Green Power Commands
The following Green Power commands are supported by default translations:
Command
Description
0x10
Recall scene #1
0x11
Recall scene #2
0x12
Recall scene #3
0x13
Recall scene #4
0x14
Recall scene #5
0x15
Recall scene #6
0x16
Recall scene #7
0x17
Recall scene #8
0x18
Store scene #1
0x19
Store scene #2
0x1A
Store scene #3
0x1B
Store scene #4
0x1C
Store scene #5
0x1D
Store scene #6
0x1E
Store scene #7
0x1F
Store scene #8
0x20
Turn Off
0x21
Turn On
0x22
Toggle
0x69
Generic Press
0x6A
Generic Release
7.8.1.2.
Generic Switch Commissioning
This product provides enhanced support for latest generation Green Power generic switches with the
ability to distinguish short (< 1 second) and long (> 1 second) presses. In fact, a generic switch
behaves like a physical switch directly connected to the high-voltage input lines, resulting in a
consistent user experience. Each contact of a switch is commissioned separately, such that the desired
button layout can be achieved on any generic switch. First commission button A, then button B, then C
and so forth. Depending on the number of commissioned contacts, the behaviour is different.
Number of
Commissioned
Contacts
Behavior
1
Press
Toggles the output, i.e. turns it on when it is off, and turns it off when it is on
2
Press Button A
Turns the output on
Press Button B
Turns the output off
3
Press Button A
Turns the output on
Press Button B
Turns the output off
Press Button C
Toggles the output, i.e. turns it on when it is off, and turns it off when it is on