16
sunMAX
™
Solar User Guide
Flashing
Flashing
is placed over each roof mount and helps ensure a watertight installation when positioned properly .
The upper edge of the
Flashing
should always be covered by the third course of shingles to prevent water
from entering underneath the
Flashing
. The upper edge of the
Flashing
should be covered by at least ¼"
(6 mm) of the third course of shingles. The lower edge of the
Flashing
should not extend beyond the edge
line of the first course of shingles .
Incorrect
Flashing should not hang over
the edge of the first course of
shingles.
Correct
Flashing reaches past the second
course of shingles and is positioned
underneath the third course.
Incorrect
Flashing is exposed and does
not sit underneath the third
course of shingles.
Flashing is positioned just above the
first row of shingles where the roof
mount was installed.
Correct
Flashing is positioned above the
first row of shingles where the roof
mount was installed.
Correct
Correct
The second course of shingles have been
trimmed around the flashing to position
it higher underneath the third course.
First Course
Second Course
Third Course
Remove any nails that
interfere with the proper
placement of flashing on
the roof’s surface.
Jumper Cables
Jumper Cables
, model SM-JC-4C-5, have a male connector and a female connector, one on each end . Each
Jumper Cable
attaches to the inside edge underneath the
AC Modules
using
Cable Support Clips
.
Jumper Cables
are used to connect adjacent rows of
AC Modules
together within a single array . In a multi-row
system,
Y-Cables
alternate their orientation, ending with a male or female connector every other row .