Solar Module

 Installation Manual (UL)

www.canadiansolar.com

Headquarters

545 Speedvale Avenue West,Guelph, 
Ontario, Canada N1K 1E6
Tel: +1-519-837-1881  Fax: +1-519-837-2550
Email: [email protected]

Germany

Landsberger Strasse 94, 80339 Munich, Germany
Tel:  +49 (0) 89-51 996 89-0 
Fax: +49 (0) 89-51 996 89-11
Email: [email protected]

Italy

Via Antonio Salandra, 18 00187 Roma Italy
Tel: +39 06-4227-2272   Fax +39 06-4227-4000
Email: [email protected]

Spain

c/ Josefa Valcarcel, 8. 2nd floor, E-28027 Madrid, Spain
Tel:  +34 91 320 28 84
Fax: +34 91 320 84 38
Email: [email protected]

Tel: 

USA

 

12657 Alcosta Blvd, Suite 140, San Ramon, CA 94583
Tel: +1-925-866-2700  Fax: +1-925-866-2704
Email: [email protected]

Japan

Round-Cross Shinjuku 5-Chome 8F, 5-17 Shinjuku Shinjuku-ku, 
Tokyo Japan 160-0022
Tel: 03-5291-8591  Fax: 03-5291-8596
Email: [email protected]

Korea

 

201, SK HUB Officetel, 708-26, Yeoksam-Dong, Kangnam-gu, 
Seoul, Korea
Tel: (02) 539-7541  Fax: (02) 539-7505
Email: [email protected]

Singapore

101 Thomson Road, #15-03 United Square
Singapore 307591
Tel: +65 65729050    Fax: +65 62594690

China 

199 Lushan Road, Suzhou New District, Jiangsu, China, 215129
Tel: +86 (512) 6690-8088
Email: [email protected]

www.canadiansolar.com

Australia

Unit 3B, North Rydelink Business Park 277-283 Lane Cove Road
Macquarie Park, NSW 2113, Australia

 +61 (2) 9889 4395

Email: [email protected]

Summary of Contents for CS Series

Page 1: ... 12657 Alcosta Blvd Suite 140 San Ramon CA 94583 Tel 1 925 866 2700 Fax 1 925 866 2704 Email inquire us canadiansolar com Japan Round Cross Shinjuku 5 Chome 8F 5 17 Shinjuku Shinjuku ku Tokyo Japan 160 0022 Tel 03 5291 8591 Fax 03 5291 8596 Email inquire jp canadiansolar com Korea 201 SK HUB Officetel 708 26 Yeoksam Dong Kangnam gu Seoul Korea Tel 02 539 7541 Fax 02 539 7505 Email inquire kr canad...

Page 2: ...thes etc to prevent direct contact with 30VDC or greater and to protect your hands from sharp edges during the installation Use electrical insulated tools to reduce the risk of electric shock Remove all metallic jewelry prior to installation to reduce the chance of accidental exposure to live circuits Cover the front of the modules in the PV array with an opaque material to halt production of elec...

Page 3: ...tand all expected loads including wind and snow loads A minimum clearance of 6 5 mm 1 4 of an inch or more between modules is required to allow for thermal expansion of the frames Small openings for water draining on the underside of the module should not be blocked after mounting Optimum orientation and tilt Find out the optimum orientation and tilt of the PV modules for your region to achieve th...

Page 4: ...er from the specifications then there is a wiring fault Correct connection of plug connectors Make sure that the connection is safe and tight The plug connector should not receive outer stress The connector should only be used to connect the circuit It should never be used to turn the circuit on and off Use of suitable materials Use special solar cable and suitable plugs only wiring should be plac...

Page 5: ...dditional mounting points should be used System designer and installer are responsible for load calculations and for proper support structure design Modules should be bolted at the following hole locations depending on the configuration and load as verified by the test method in IEC 61215 Table 6 1 Authorized attachments for bolting method Bolting on short side frame except for 6X series Uplift lo...

Page 6: ... PX CS6P 245P PM PX CS6P 250P PM PX Model Type Maximum power Pmax W Max Series Fuse Rating A Weight Kg Overall Dimension mm Operating Voltage Vmp V Open Circuit Voltage Voc V Short Circuit Current Isc A Operating current Imp A 20 30 1602X1061X40 10 00 20 30 1602X1061X40 10 00 10 00 19 00 1638 982 40 3 00 3 00 2 40 534 350 25 2 40 534 350 25 5 00 5 00 10 00 10 00 5 10 608 666 35 5 10 608 666 35 6 5...

Page 7: ... copper conductor wire and allow connecting the system to equipment ground connector Model Type Maximum power Pmax W Max Series Fuse Rating A Weight Kg Overall Dimension mm Operating Voltage Vmp V Open Circuit Voltage Voc V Short Circuit Current Isc A Operating current Imp A CS6P 255P PM PX CS6P 260P PM PX CS6P 265PM CS6P 270PM CS6P 275PM CS6A 160M CS6A 165M CS6A 170M CS6A 175M CS6A 180M CS6A 185M...

Page 8: ...n manual from UNIRAC or to UL SM_En A0 Technical B 4 GROUNDING METHOD D Rapid2 Grounding Middle Clamps Used in conjonction with any Schletter module mounting rail INTERTEK certified 2 Schletter Rapid Grounding Clamps are used to create a grounding path between the module frame and the mounting rail An integrated grounding pin ensures bonding to the module frame by penetrating the frame coating 2 T...

Page 9: ...clamps on the long side the allowed range depends on the module type Authorized range for clamping as a function of model type Model type CS5A CS5P CS6A CS6P CS5T CS6X A1 range mm 220 380 220 390 220 340 240 410 340 550 B1 range mm 330 400 330 400 270 330 340 410 410 490 A2 range mm 170 200 220 270 200 250 200 250 200 250 A1 A1 A1 A1 B1 B1 B1 B1 Mounting rails may run perpendicularly or parallel t...

Page 10: ... used for PV modules that are not compatible with flange clamp style Claws The Long Claw attaches at the module mounting holes using standard bolting method Refer to paragraph 6 1 for suitable torque and fastening requirements Step 4 Mount Modules to Supports Step 5 Electrical Grounding Refer to B 5 GROUNDING METHOD E Grounding for Grizzly Bear FR Gen II SYSTEM for grounding assembly and requireme...

Reviews: