Maintenance
39
Printed: 01/2018 Subject to change!
TopLineUserManual.docx
6.4.3 Replacement of Quartz Heater Lamps
Warning:
Remove all electrical power supplied to the unit by
unplugging the power cord or electrical shock could result. If the
unit is permanently wired, the circuit breaker must be used to
disconnect power.
1. Loosen two screws on both ends to remove the upper half of
the lamps socket.
2. Use a 7mm wrench or nut driver and remove nut from lamps.
Caution:
It is recommended not to touch heater with hands. Use
gloves when replacing or damage to heater lamps could result.
3. Install new heater. Make sure to use the bras washer and
securely tightening nut for heater wire. Hold the metal part of
the lamp to avoid breaking it from the glass finally unwrap the
paper around the lamp.
Summary of Contents for Top Line
Page 1: ...User Manual Rotisseries Top Line RT Series ...