Operation
21
Printed: 01/2018 Subject to change!
TopLineUserManual.docx
5.2.4 Programming the digital electronic
To enter the programming level, push and hold the Programming Button
until “COdE” is shown in the
Temperature Display
and “100” is shown in the Time Display
. Now release the Programming
Button
. Use the up/down button
/
to adjust to ‘555’ and confirm the code by pushing the
Programming Button
.
Additional information on how to quickly adjust numbers with the up/down button
/
:
Push and hold the up/down button
/
to quickly move forward:
Start:
+1
After 10 steps
+10
After 10 steps
+100
“PROG” is shown in the Temperature Display
. Confirm to enter the programming level by pushing the
Programming Button
.
A) The Temperature Display
now shows number and step of the first program “Pr1.1”.
Use the up/down button
/
to adjust the desired temperature and confirm your setting by pushing the
Programming Button
. Use the up/down button
/
to adjust the desired time as [hh:mm] and
confirm your setting by pushing the Programming Button
.
B) The Temperature Display
now shows number and step of the first program “Pr1.2”.
Use the up/down button
/
to adjust the desired temperature and confirm your setting by pushing the
Programming Button
. Use the up/down button
/
to adjust the desired time as [hh:mm] and
confirm your setting by pushing the Programming Button
.
C) The Temperature Display
now shows number and step of the first program “Pr1.3”.
Use the up/down button
/
to adjust the desired temperature and confirm your setting by pushing the
Programming Button
. Use the up/down button
/
to adjust the desired time as [hh:mm] and
confirm your setting by pushing the Programming Button
.
Repeat A-C for the remaining programs 2 - 20.
If a program is not needed, just enter “000” for the temperature of the first step of a program. All other
steps will be skipped and the next program appears.
Once the time setting for “Pr20.3” is done, or no button is pushed for
15 seconds
, the controller will
leave the programming level and go back to operating level.
In case a wrong code has been entered, “FALS” is shown in the Temperature Display
and you have
to wait for the time out (app. 15 sec.) before a code can be entered again.