UAV-1002373-001
43
DRAFT
– TSO PENDING
C.3 Third-party EFIS
C.3.1 ping200X Configuration
Configure the ping200X as appropriate, ensuring the following values have
been updated from defaults:
Parameter
Value
In Protocols
UCP and Apollo
Out Protocols
Apollo
Serial Port Baud Rate
57600 or as appropriate
Baro Altitude Source
External
C.3.2 EFIS Configuration
The following third-party EFIS displays have the capability to send
barometric pressure altitude data and control the mode and squawk
functions of the ping200X through any available RS-232 serial output.
ping200X configuration must still take place through the
“ping200X Control
& Config” Windows application.
Known Compatible EFIS
GRT
MINI-B
MINI-AP
MINI-X
Sport EX
Horizon EX
MGL
iEFIS
Only the serial OUTPUT is required. It should be set to the following
parameters.
Characteristics
Specifications
Physical
RS-232
Rate and properties
57,600 bps 8N1 (or as configured on
ping200X)
Protocol
SL70, STX 165R, or UCP