SMoGHoG

®

SHM Series Models 

6

3.5  ELECTRICAL CONNECTION

the SHM is available with various controls configurations. 

refer  to  the  section  headings  below  and  follow  the 

section instructions that best align with your specific unit. 

Multiple sections may apply to the same unit. the SHM 

customer  electrical  connections  are  located  on  the  rear 

of  the  unit  as  shown  in  figure  1B.  the  supply  voltage 

and fLa will be noted on the nameplate. the blower and 

pulse  cleaning  system  controls  are  factory  pre-wired  for 

operation. the touchscreen controls are also pre-wired for 

the integral option, but require field wiring and connections 

for the remote display enclosure option. Wiring diagrams 

for  the  various  SHM  controls,  blower  arrangement  and 

supply voltage options are available within the appendix 

of  this  manual.  note  that  the  SHM  does  not  contain 

the  main  disconnect  or  fuses  for  the  supply  power. 

electrical installation should be completed by a qualified 

professional  and  done  in  accordance  with  all  applicable 

codes and regulations.
Power cord and connection into unit will be supplied by 

the customer.
unit is available in the voltages shown below:

TABLE 1

SHM Voltage and Full Load Amps

Note: 

When making the main power connections to the 

unit, fan rotation check is not required.

 

VOLT

PH

#

BLWR

HZ

RPM

FLA

XFMR

208

3

1

50-60

3370

6.5

---

230

3

1

50-60

3370

5.7

---

240

3

1

50-60

3370

5.5

---

380

3

1

50-60

4200

6.7

---

480

3

1

50-60

4200

5.5

---

575

3

1

50-60

4200

---

6kVA

208

3

2

50-60

3370

13.5

---

230

3

2

50-60

3370

11.5

---

240

3

2

50-60

3370

11.0

---

380

3

2

50-60

4200

13.9

---

480

3

2

50-60

4200

11.0

---

575

3

2

50-60

4200

---

10kVA

208

3

3

50-60

3370

18.9

---

230

3

3

50-60

3370

16.4

---

240

3

3

50-60

3370

15.5

---

380

3

3

50-60

4200

19.1

---

480

3

3

50-60

4200

15.5

---

575

3

3

50-60

4200

---

15kVA

FOR BASIC CONTROLS ON SHM-11, SUBTRACT

0.5 AMP FROM FLA VALUES ABOVE. 

TABLE 2

Wire Diagrams

3.5.1 ELECTRICAL SUPPLY POWER

the  main  power  supply  is  connected  to  the  SHM  unit 

through  a  1˝  FNPT  coupling  located  on  the  rear  of  the 

unit shown in figure 1B. after feeding wires through the 

coupling,  terminations  are  made  on  the  main  bus  bar 

terminal for each phase and frame ground connection. the 

rear electrical panel also contains the unit circuit breakers 

and  dc  power  supply  for  the  controls  components. 

utilize  table  1  for  wire,  fuse  and  disconnect  sizing  for 

your  respective  product  model.  A  second  plugged  1˝ 

fnPt coupling is also located on the rear of the cabinet 

for  low  optional  voltage  connections  using  the  Machine 

interlock  feature  to  automate  operation.  ensure  that  the 

rear electrical panel cover is in place and secured prior to 

operating the unit. refer to the electrical wiring diagrams 

in table 2 for additional wiring information.

3.5.2 ELECTRICAL BASIC CONTROLS

the basic electrical controls consist of a thermal motor 

protection disconnect on the side of the unit. this is set 

for  the  fLa  of  the  single  blower  motor.  this  is  factory 

prewired to the blower motor. When installing this unit in 

the field the customer will connect their factory power to 

the disconnect on the line side of the thermal protector. 

the disconnect on/off will supply power to the unit and 

allow the blower on/off switch on the front of the unit to 

control the blower. inside the door on the front of the unit 

there is a blower speed adjustment. this will control the 

speed of the blower from off to full speed. this should 

be  adjusted  by  the  customer  to  meet  their  process 

requirements.

Descrip�on of Wire Diagram 

Appendix

Basic Controls 

A1

Remote Panel Basic Controls

A2

One Blower & Controls

A3

Two Blower & Controls

A4

Three Blower & Controls

A5

Remote Panel Touch Controls

A6

One Blower & Remote Controls

A7

Two Blower & Remote Controls

A8

Three Blower & Remote Controls

A9

Transformer 575:480

A10

Summary of Contents for SMOGHOG SHM-C Series

Page 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL...

Page 2: ...following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL _____________________________________________________________...

Page 3: ...n 8 3 6 1 Installation Procedure for After Filters 8 3 6 1 1 Hold Down 8 3 6 1 2 Enclosed 10 3 7 Drains 10 4 UNIT OPERATION 10 4 1 Start up 10 4 2 System Operation 10 4 2 1 Airflow Adjustment Using Ma...

Page 4: ...erials and vapors such as gasoline away from the unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage O...

Page 5: ...e assistance in the installation startup operation maintenance or troubleshooting of your air cleaning equipment contact your local UAS sales representative 2 1 SMOGHOG NOMENCLATURE SMOGHOG oil mist a...

Page 6: ...REV 16I SMOGHOG SHM Series Models 2 FIGURE 1B SHM Equipment Description 61 10113 FIGURE 1A SHM Equipment Description...

Page 7: ...the unit in each corner Do not lift the unit by placing lift truck forks through the legs on the underside of the unit Filter Elements Stage 1 Mist Stop fine fiber aluminum mesh Stage 2 Primary coale...

Page 8: ...ering drawings of your specific equipment and options will be provided These and all available documentation for your system should be thoroughly reviewed prior to beginning any installation work This...

Page 9: ...guration Secure the unit at all four corners using the standard unit feet or extension leg foot pads At least one of the two holes per foot pad on the extension legs should be secured See Figure 1 for...

Page 10: ...S ON SHM 11 SUBTRACT 0 5 AMP FROM FLA VALUES ABOVE TABLE 2 Wire Diagrams 3 5 1 ELECTRICAL SUPPLY POWER The main power supply is connected to the SHM unit through a 1 FNPT coupling located on the rear...

Page 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection...

Page 12: ...INTERLOCK DRY CONTACT The customer has the option to control the SHM On Off operation with the oil mist generating equipment or process This will allow the operator to control the SHM with a dry conta...

Page 13: ...REV 16I SMOGHOG SHM Series Models 9 61 10115 Figure 5B SHM Filter Removal Installation Figure 5A SHM Filter Removal Installation...

Page 14: ...other equipment will need to be engaged as well 7 Verify performance of the system by measuring airflow or evaluating capture at each collection point It is recommended to record baseline performance...

Page 15: ...fter Filter monitoring or unique screens required for a special application These screens are based on customer order and loaded at the factory Figure 6 4 3 2 Standard Format The icon key Table 3 outl...

Page 16: ...arrows The second method of airflow adjustment is to touch the box that shows the percentage of the airflow A number pad will be shown in a pop up screen You can enter any number between 20 and 100 T...

Page 17: ...re not password protected To select one of the items just touch the box with the item you want to make a change too The Locked Settings selection will allow the operator to select options of the syste...

Page 18: ...cked Settings group on the Customer settings screen The Auto Flow is an option that is selected at order time and loaded into the SHM at the factory The Auto Flow Settings will allow the unit to maint...

Page 19: ...r hose This filter can be replaced if contaminants become impossible to remove or due to excessive wear Always wear proper PPE including goggles dust mask and work gloves when installing or replacing...

Page 20: ...into place prior to hanging the individual bags loops For units that are two filters deep be sure to push the first filter all way toward the back of the primary filter cabinet until it contacts the...

Page 21: ...ker Open rear panel on unit and switch breaker if necessary Loose or disconnected wires Inves gate wiring in the rear panel Disconnect is switched to OFF posi on Switch disconnect to ON posi on Improp...

Page 22: ...LTER HEPA 99 97 0 3 m 5 33 10117 ALUMINUM MESH PRE FILTER 6 33 10128 COALESCING CARTRIDGE FILTER 9 OD PEACH MEDIA 33 LENGTH 3 33 10129 CABINET AFTER FILTER MICROGUARD O M 95 0 3 m 7 39 10008 0006 CONT...

Page 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F...

Page 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682...

Page 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799...

Page 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695...

Page 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696...

Page 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697...

Page 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802...

Page 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798...

Page 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797...

Page 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796...

Page 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717...

Page 34: ...This page intentionally left blank...

Page 35: ...This page intentionally left blank...

Page 36: ...anty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice...

Reviews: