5.  SERVICE

   Before servicing equipment:

  •  Wear appropriate protective equipment when 

servicing oil mist collector.

  • Disconnect and lockout electrical power to the unit 

and control panel.

5.1  GENERAL MAINTENANCE GUIDELINES

Proper maintenance of the SHM is essential for the unit 

to  provide  excellent  oil  mist  collection  capabilities  and 

long‐term  service.  By  keeping  the  unit  well‐maintained, 

you  will  also  reduce  operating  and  parts  replacement 

costs.  a  scheduled  preventive  maintenance  program, 

specifically  designed  for  the  SHM  and  its  associated 

components,  is  the  best  possible  method  to  ensure  the 

unit stays in proper working order.
refer  to  Section  6  for  troubleshooting  guide  to  correct 

any problems that may occur with your oil mist collection 

unit.  if  the  problem  or  condition  continues,  contact  uaS 

customer service for assistance.

5.2 FILTER SERVICE

automatic  filter  replacement  warnings  should  display  on 

units so equipped.
on unequipped units, when the primary filters reach the 

point  of  not  being  able  to  maintain  proper  unit  function 

they must be replaced.

to  order  filters,  contact  your  uaS  sales  representative. 

identify your filter part number from your sales order, your 

unit nameplate, or the inside cover of this manual.
the aluminum mesh pre-filter can be washed and rinsed 

with a moderately powerful spray from a power-washer or 

hose. this filter can be replaced if contaminants become 

impossible to remove or due to excessive wear.

always wear proper PPe including goggles, dust mask 

and  work  gloves  when  installing  or  replacing  filter 

elements.  oil  accumulated  on  the  filter  elements  can 

result in irritation of the lungs, skin, and / or eyes.

remove used filter elements from the collector and dispose 

of properly, in accordance with governing restrictions. Be 

sure there is no excess oil or residue build-up inside the 

primary filter cabinet. clean or rinse as necessary. inspect 

all  filter  sealing  cam  bars  and  filter  support  parts  for 

unusual signs of wear or failure. checking all gaskets and 

seals is recommended at this time, as well as replacement 

if necessary.
the  surface  of  the  filter  element  can  be  damaged  as  a 

result of improper moving or handling. care must be taken 

to prevent any damage to the filter media. 
inspect  each  filter  element  for  damage  from  shipping, 

storage or handling. do not use damaged elements, they 

may leak or fail prematurely.
review installation procedures for filter elements before 

beginning the installation procedures and accessing the 

oil mist collector. follow the proper lockout, tagout.
numbers in figure 5 coordinate directly with numbering 

below.

 

!

  D A N G E R

    

CAUTION

Task

Maintenance Interval

Check Sump Level, Verify Proper Drainage Weekly (increased frequency may be necessary)
Check For Accumulated Material

Monthly (or when filters are replaced or bin emp�ed)

*Add to this list and adjust the maintenance interval as necessary based on applica�on.

TABLE 4

Maintenance Schedule

Summary of Contents for SMOGHOG SHM-C Series

Page 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL...

Page 2: ...following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL _____________________________________________________________...

Page 3: ...n 8 3 6 1 Installation Procedure for After Filters 8 3 6 1 1 Hold Down 8 3 6 1 2 Enclosed 10 3 7 Drains 10 4 UNIT OPERATION 10 4 1 Start up 10 4 2 System Operation 10 4 2 1 Airflow Adjustment Using Ma...

Page 4: ...erials and vapors such as gasoline away from the unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage O...

Page 5: ...e assistance in the installation startup operation maintenance or troubleshooting of your air cleaning equipment contact your local UAS sales representative 2 1 SMOGHOG NOMENCLATURE SMOGHOG oil mist a...

Page 6: ...REV 16I SMOGHOG SHM Series Models 2 FIGURE 1B SHM Equipment Description 61 10113 FIGURE 1A SHM Equipment Description...

Page 7: ...the unit in each corner Do not lift the unit by placing lift truck forks through the legs on the underside of the unit Filter Elements Stage 1 Mist Stop fine fiber aluminum mesh Stage 2 Primary coale...

Page 8: ...ering drawings of your specific equipment and options will be provided These and all available documentation for your system should be thoroughly reviewed prior to beginning any installation work This...

Page 9: ...guration Secure the unit at all four corners using the standard unit feet or extension leg foot pads At least one of the two holes per foot pad on the extension legs should be secured See Figure 1 for...

Page 10: ...S ON SHM 11 SUBTRACT 0 5 AMP FROM FLA VALUES ABOVE TABLE 2 Wire Diagrams 3 5 1 ELECTRICAL SUPPLY POWER The main power supply is connected to the SHM unit through a 1 FNPT coupling located on the rear...

Page 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection...

Page 12: ...INTERLOCK DRY CONTACT The customer has the option to control the SHM On Off operation with the oil mist generating equipment or process This will allow the operator to control the SHM with a dry conta...

Page 13: ...REV 16I SMOGHOG SHM Series Models 9 61 10115 Figure 5B SHM Filter Removal Installation Figure 5A SHM Filter Removal Installation...

Page 14: ...other equipment will need to be engaged as well 7 Verify performance of the system by measuring airflow or evaluating capture at each collection point It is recommended to record baseline performance...

Page 15: ...fter Filter monitoring or unique screens required for a special application These screens are based on customer order and loaded at the factory Figure 6 4 3 2 Standard Format The icon key Table 3 outl...

Page 16: ...arrows The second method of airflow adjustment is to touch the box that shows the percentage of the airflow A number pad will be shown in a pop up screen You can enter any number between 20 and 100 T...

Page 17: ...re not password protected To select one of the items just touch the box with the item you want to make a change too The Locked Settings selection will allow the operator to select options of the syste...

Page 18: ...cked Settings group on the Customer settings screen The Auto Flow is an option that is selected at order time and loaded into the SHM at the factory The Auto Flow Settings will allow the unit to maint...

Page 19: ...r hose This filter can be replaced if contaminants become impossible to remove or due to excessive wear Always wear proper PPE including goggles dust mask and work gloves when installing or replacing...

Page 20: ...into place prior to hanging the individual bags loops For units that are two filters deep be sure to push the first filter all way toward the back of the primary filter cabinet until it contacts the...

Page 21: ...ker Open rear panel on unit and switch breaker if necessary Loose or disconnected wires Inves gate wiring in the rear panel Disconnect is switched to OFF posi on Switch disconnect to ON posi on Improp...

Page 22: ...LTER HEPA 99 97 0 3 m 5 33 10117 ALUMINUM MESH PRE FILTER 6 33 10128 COALESCING CARTRIDGE FILTER 9 OD PEACH MEDIA 33 LENGTH 3 33 10129 CABINET AFTER FILTER MICROGUARD O M 95 0 3 m 7 39 10008 0006 CONT...

Page 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F...

Page 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682...

Page 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799...

Page 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695...

Page 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696...

Page 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697...

Page 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802...

Page 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798...

Page 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797...

Page 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796...

Page 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717...

Page 34: ...This page intentionally left blank...

Page 35: ...This page intentionally left blank...

Page 36: ...anty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice...

Reviews: