background image

reV: 16i

SMoGHoG

®

SHM Series Models 

1

1.  IMPORTANT NOTICE

this  manual  contains  important  safety  information  and 

precautionary measures. it is impossible to list all potential 

hazards associated with every collection system in each 

application.  Proper  use  of  the  equipment  should  be 

discussed with United Air Specialists, Inc. (UAS) or your 

local  UAS  representative.  operating  personnel  should 

be  aware  of,  and  adhere  to,  the  most  stringent  safety 

procedures.

2.  INTRODUCTION

thank you for selecting uaS oil mist collection equipment 

to  assist  you  in  your  commitment  to  a  clean  and  safe 

environment.  We  trust  that  in  purchasing  our  product,  

you  have  recognized  our  commitment  to  offering  air 

cleaning  equipment  which  is  engineered  to  each  oil 

mist  collection  need  and  manufactured  to  the  highest 

standards. if at any time you have a question about oil mist 

collection,  please  do  not  hesitate  to  call  your  local  uaS 

representative. 
the  purpose  of  this  manual  is  to  provide  the  proper 

operating  and  maintenance  guidelines  for  the  SHM 

system  supplied  by  uaS.  as  you  review  this  manual,  

refer  to  figure  1  for  assistance  in  identifying  oil  mist 

collector parts.
the SHM oil mist collector has been designed to provide 

you  with  exceptional  oil  mist  collection  capabilities  and 

reliable,  long‐term  field  operation.  We  suggest  that  you 

thoroughly  review  this  manual  prior  to  installation  and 

startup of your system.
if  your  SHM  has  optional  equipment  included  as  part  of 

your order, specific operations and maintenance manuals 

for these accessory systems will be included. if applicable, 

site  specific  installation  and  other  drawings  will  also  be 

included.
if  you  require  assistance  in  the  installation,  startup, 

operation,  maintenance  or  troubleshooting  of  your 

air  cleaning  equipment,  contact  your  local  uaS  sales 

representative.

2.1 SMOGHOG NOMENCLATURE

SMoGHoG oil mist air cleaners are available in a variety 

of  configurations  and  sizes.  the  model  string  for  each 

given unit represents the base configuration. the model 

number completely identifies the design and can be found 

on the unit nameplate. SHM models are defined according 

to descriptions listed below (see bold):

 SHM-XXX

 

   

              filter type

 

              Quantity of filter modules deep

            

Quantity of filter modules wide 

  C

  - PeacH Saturated depth  

  F

  - fiberglass Bag filter

Models  SHM-11C, SHM-12C, SHM-21C, SHM-31C, 

SHM-22C, & SHM-32C

Models  SHM-11F, SHM-12F, SHM-21F, SHM-31F,  

SHM-22F, SHM-32F

the  SMoGHoG  is  a  free  standing,  self  contained, 

multistage, oil mist filtering unit with inlet sump or direct 

mount  flange,  mechanical  prefilter,  primary  filter,  blower 

cabinet,  and  controls.  optional  after  filters  are  available 

for third stage filtration.

2.2 EQUIPMENT DESCRIPTION

this  section  will  briefly  describe  each  component  in  the 

SHM and its role in the system’s operation.

Inlet Sump

Most  units  will  include  an  inlet  sump  with  multiple  10˝ 

inlets  where  all  incoming  dirty  air  will  enter.  the  sump 

provides  an  expanded  volume  allowing  contaminant  to 

drop out of the airsteam reducing loading on the filters.  a 

1-1/2” fnPt coupling is included at the peak of a sloped 

bottom allowing the collected contaminant to be reclaimed 

or drained. 

Filter Cabinet

each  unit  has  a  filter  access  door  that  provides  access 

to  both  the  prefilter  and  primary  filter  for  service  and 

replacement. the mesh prefilter rests on tracks near the 

bottom of the cabinet. the PeacH coalescing filter option 

are mounted on a removable cassette secured by a cam 

bar mechanism. the fiberglass bag option uses a hanging 

rod system.

Summary of Contents for SMOGHOG SHM-C Series

Page 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL...

Page 2: ...following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL _____________________________________________________________...

Page 3: ...n 8 3 6 1 Installation Procedure for After Filters 8 3 6 1 1 Hold Down 8 3 6 1 2 Enclosed 10 3 7 Drains 10 4 UNIT OPERATION 10 4 1 Start up 10 4 2 System Operation 10 4 2 1 Airflow Adjustment Using Ma...

Page 4: ...erials and vapors such as gasoline away from the unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage O...

Page 5: ...e assistance in the installation startup operation maintenance or troubleshooting of your air cleaning equipment contact your local UAS sales representative 2 1 SMOGHOG NOMENCLATURE SMOGHOG oil mist a...

Page 6: ...REV 16I SMOGHOG SHM Series Models 2 FIGURE 1B SHM Equipment Description 61 10113 FIGURE 1A SHM Equipment Description...

Page 7: ...the unit in each corner Do not lift the unit by placing lift truck forks through the legs on the underside of the unit Filter Elements Stage 1 Mist Stop fine fiber aluminum mesh Stage 2 Primary coale...

Page 8: ...ering drawings of your specific equipment and options will be provided These and all available documentation for your system should be thoroughly reviewed prior to beginning any installation work This...

Page 9: ...guration Secure the unit at all four corners using the standard unit feet or extension leg foot pads At least one of the two holes per foot pad on the extension legs should be secured See Figure 1 for...

Page 10: ...S ON SHM 11 SUBTRACT 0 5 AMP FROM FLA VALUES ABOVE TABLE 2 Wire Diagrams 3 5 1 ELECTRICAL SUPPLY POWER The main power supply is connected to the SHM unit through a 1 FNPT coupling located on the rear...

Page 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection...

Page 12: ...INTERLOCK DRY CONTACT The customer has the option to control the SHM On Off operation with the oil mist generating equipment or process This will allow the operator to control the SHM with a dry conta...

Page 13: ...REV 16I SMOGHOG SHM Series Models 9 61 10115 Figure 5B SHM Filter Removal Installation Figure 5A SHM Filter Removal Installation...

Page 14: ...other equipment will need to be engaged as well 7 Verify performance of the system by measuring airflow or evaluating capture at each collection point It is recommended to record baseline performance...

Page 15: ...fter Filter monitoring or unique screens required for a special application These screens are based on customer order and loaded at the factory Figure 6 4 3 2 Standard Format The icon key Table 3 outl...

Page 16: ...arrows The second method of airflow adjustment is to touch the box that shows the percentage of the airflow A number pad will be shown in a pop up screen You can enter any number between 20 and 100 T...

Page 17: ...re not password protected To select one of the items just touch the box with the item you want to make a change too The Locked Settings selection will allow the operator to select options of the syste...

Page 18: ...cked Settings group on the Customer settings screen The Auto Flow is an option that is selected at order time and loaded into the SHM at the factory The Auto Flow Settings will allow the unit to maint...

Page 19: ...r hose This filter can be replaced if contaminants become impossible to remove or due to excessive wear Always wear proper PPE including goggles dust mask and work gloves when installing or replacing...

Page 20: ...into place prior to hanging the individual bags loops For units that are two filters deep be sure to push the first filter all way toward the back of the primary filter cabinet until it contacts the...

Page 21: ...ker Open rear panel on unit and switch breaker if necessary Loose or disconnected wires Inves gate wiring in the rear panel Disconnect is switched to OFF posi on Switch disconnect to ON posi on Improp...

Page 22: ...LTER HEPA 99 97 0 3 m 5 33 10117 ALUMINUM MESH PRE FILTER 6 33 10128 COALESCING CARTRIDGE FILTER 9 OD PEACH MEDIA 33 LENGTH 3 33 10129 CABINET AFTER FILTER MICROGUARD O M 95 0 3 m 7 39 10008 0006 CONT...

Page 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F...

Page 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682...

Page 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799...

Page 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695...

Page 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696...

Page 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697...

Page 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802...

Page 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798...

Page 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797...

Page 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796...

Page 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717...

Page 34: ...This page intentionally left blank...

Page 35: ...This page intentionally left blank...

Page 36: ...anty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice...

Reviews: