background image

10HP CYCLONE 

AUTO CLEAN TIMING SYSTEM

Summary of Contents for T Flux 10

Page 1: ...10HP CYCLONE AUTO CLEAN TIMING SYSTEM...

Page 2: ...ty For Dust Collectors Power Connections Motor Specifications Grounding Instructions Key Features and Components Functional Description Product Specifications Unpacking Assembly General Tool Assembly...

Page 3: ...feels dangerous don t try it Figure out an alternative procedure that feels safer REMEMBER Your personal safety is your responsibility This machine was designed for certain applications only We strong...

Page 4: ...e machine and in this manual Failure to comply with all of these warnings may cause serious injury 2 Replace the warning labels if they become obscured or removed 3 This 3HP Portable Cyclone Dust Coll...

Page 5: ...rags are removed away from the machine before turning on 14 Keep safety guards in place at all times when the machine is in use If removed for maintenance purposes use extreme caution and replace the...

Page 6: ...e running unattended Turn the power off and do not leave the machine until it comes to a complete stop 29 Never operate or run the machine without closing the drum up against the lid Failure to do so...

Page 7: ...red areas and benches invite accidents DON T USE IN DANGEROUS ENVIRONMENT Don t use this unit in damp or wet locations or expose it to rain Keep work area well lighted KEEP CHILDREN AND VISITORS AWAY...

Page 8: ...urces Do not operate the dust collector in areas were explosion risks are high Areas of high risk include but are not limited to areas near pilot lights open flames or other ignition sources Fire supp...

Page 9: ...ection bags or drum to avoid the buildup of fine dust that can increase the risk of fire Make sure to regularly clean the surrounding area where the machine is operated excessive dust buildup on overh...

Page 10: ...S DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS MOTOR SPECIFICATIONS Your machine is wired for 220 volts 60 HZ alternating current Before connecting the machine to the pow...

Page 11: ...nection of the equipment grounding wire can result in a risk of electric shock The wire with green insulation with or without yellow stripes is the equipment grounding wire If repair or replacement of...

Page 12: ...nds clockwise and another 10 seconds counterclockwise When you switch OFF the unit after 30 seconds when the fan comes to a complete stop the canister filters will clean for 10 seconds clockwise and a...

Page 13: ...minute Max static pressure 16 8 Inches of water Fan size 18 5 Inlet 12 Switch High frequency remote control switch Collection capacity 54 gallon Octagon drum x 2sets Packing Size L x W x H 100 4 x 45...

Page 14: ...QUANTITY Figure 1 A Motor B Support panel C Cyclone D Canister filter E Support panel F Control panel and box G Hand held remote controller H Front horizontal panel Report any missing or damaged parts...

Page 15: ...hex wrench To assemble your dust cyclone follow these steps For your own safety do not connect the machine to the power source until the machine is completely assembled Please also make sure that you...

Page 16: ...3 8 1 hex bolts and 8 3 8 OD23 2t flat washers and 8 3 8 lock nuts for the two side bolt holes Step Three Secure the 2 lower upright supports to the right side of the machine when facing the control p...

Page 17: ...o the front of the unit facing the control side Use 12 3 8 1 hex bolts 24 3 8 OD23 2t flat washers and 12 3 8 lock nuts Step Five Secure the back horizontal panel with the opening for the control pane...

Page 18: ...right side of the unit facing the control side Use 12 3 8 1 hex bolts 24 3 8 OD23 2t flat washers and 12 3 8 lock nuts Step Seven Secure the side horizontal panel to the left side of the unit facing t...

Page 19: ...vacuum suction tube connector and attach to the horizontal back panel using 4 1 4 3 4 hex bolts and 4 1 4 OD19 2t flat washers Step Nine Take the drum lid vacuum suction tube and attach to the drum li...

Page 20: ...lid vacuum suction tube and attach to the drum lid using 2 1 4 3 4 hex bolts and 2 1 4 OD19 2t flat washers Step Eleven Take the drum lid and apply the 3 6mm foam tape provided to two square center op...

Page 21: ...P Stationary Dust Cyclone Manual 20 Step Twelve Attach the lower connector to the drum lid using 16 3 8 1 hex bolts and 32 3 8 OD23 2T flat washers Step Thirteen Place the flange on top of the connect...

Page 22: ...clone funnel Attach the connector to the cyclone funnel using 6 5 16 1 1 4 hex bolts and 12 5 16 OD18 2t flat washers Step Twelve Secure the latch base plate to the front side of the drum lid using 2...

Page 23: ...the black screws off the sensor then thread the sensor through the hole on the drum lid Take the black screw and tighten the other end of the sensor that is on the inner side of the lid Step Eighteen...

Page 24: ...vided in the hardware box Step Twenty Using the white plastic pin insert the sharp point into the top end of the proximity sensor that is on top of the drum lid You will find a small hole to on top wh...

Page 25: ...enty One Secure the casters to the drum base panel using 8 3 8 OD23 2T flat washers and 4 3 8 nuts Step Twenty Two Assemble the front and back panel to the drum base using 10 5 16 5 8 Philip hd bolts...

Page 26: ...olts 12 5 16 OD18 2t flat washers and 6 5 16 nuts to secure the base And then use 16 5 16 5 8 Philip hd bolts 16 5 16 OD18 2t flat washers and 16 5 16 nuts to secure the panels to each other Step Twen...

Page 27: ...Manual 26 Step Twenty Five Assemble the latch to the drum using 4 3 16 3 8 round head thread bolts Step Twenty Six Assemble the drum vacuum suction tube to the back panel using 4 5 16 3 4 hex bolts an...

Page 28: ...the drum vacuum suction tube and use the 1 1 4 hose clamp to tighten and secure the black flex hose in place Step Twenty Eight Attach the other end of the 1 1 4 x0 8M black flex hose to the drum lid v...

Page 29: ...e Place the vacuum suction ring inside before inserting the plastic bag in the Octagon drum Step Thirty Once completing the assembly apply silicone to the inside of the drum including the base to seal...

Page 30: ...hirty One Punch out a hole in the control panel next to where the motor cord is located Refer to circled area in the location shown below Step Thirty Two Thread the power cord through the hole in the...

Page 31: ...st Cyclone Manual 30 Step Thirty Three Take the control box provided and attach to the front horizontal panel Step Thirty Four Position the control box behind the front horizontal panel and let it res...

Page 32: ...irty Five Before bolting on the control box you must first take out the control panel from the box and insert through the hole on the horizontal panel Step Thirty Six Secure the control panel from the...

Page 33: ...sed air on a regular basis to maintain maximum filtration efficiency and longer life span of the filter Auto cleaning motor The machine is equipped with an auto cleaning system that will clean the can...

Page 34: ...Open the maintenance door on the canister cover plate sitting on top of the dust chute where the gear motor is located 2 Loosen the bolt off of the rotation shaft as shown below Set the shaft aside fo...

Page 35: ...ther person loosen the 12 bolts holding the canister filter to the dust chute Carefully remove the canister filter off from the dust chute 4 With the canister filter removed use a compressed air gun t...

Page 36: ...se the spring loaded band clamp at the bottom of the filter and remove the filter bag 2 Empty or replace the filter bag and re attach using the spring loaded band clamp EMPTYING THE DRUM Periodically...

Page 37: ...nstall inlet restrictor replace weak breaker Replace batteries ensure un obstructed line of sight and signal range Inspect receiver circuit board replace if faulty Rewire or call certified service tec...

Page 38: ...line Suction route is too long or has too many sharp bends Wet lumber is clogging ducts Leaks in the duct work or too many open ports Inadequate velocity in the main suction line Wrong size ducting p...

Page 39: ...10HP Stationary Dust Cyclone Manual 38 Parts Breakdown...

Page 40: ...LT 1 2 1 1 2 4 8 FLAT WASHER 1 2 OD23 2t 4 9 FLAT WASHER 1 2 OD23 2t 4 10 MOTOR SUPPORT BASE 1 11 HEX NUT 1 2 4 12 IMPELLER 18 1 2 1 13 MOTOR WASHER 3 4 OD45 3t 1 14 MOTOR NUT 3 4 1 15 DUST CHUTE 1 16...

Page 41: ...AT WASHER 1 4 OD19 2t 28 34 DUST CHUTE SIDE PLATE LONG 2 35 HEX BOLT 3 8 3 4 8 36 FLAT WASHER 3 8 OD23 2t 8 37 HEX BOLT 1 4 3 4 20 38 FLAT WASHER 1 4 OD19 2t 20 39 DUST CHUTE SIDE PLATE SHORT 2 40 INT...

Page 42: ...M VACUUM SUCTION TUBE 2 59 HEX BOLT 1 4 3 4 4 60 FLAT WASHER 1 4 OD19 2t 4 61 DRUM LID 1 62 CANISTER FILTER 750MM 1 63 HEX BOLT 5 16 3 4 12 64 FLAT WASHER 5 16 OD18 2t 12 65 SPRING BAG CLAMP 750MM 1 6...

Page 43: ...OD18 2t 16 84 FLEX HOSE 1 1 4 2 85 HOSE CLAMP 1 1 4 4 86 DRUM BASE PANEL 2 87 DRUM WHEEL 2 8 88 FLAT WASHER 3 8 OD23 2t 16 89 HEX NUT 3 8 8 90 WINDOW 4 91 RIVET 3 2 40 92 FLAT WASHER 5 196 OD18 2t 40...

Page 44: ...T 9 6holes 1 111 FOAM TAPE 3 6mm 1 112 TOP UPRIGHT SUPPORT RIGHT 2 113 TOP UPRIGHT SUPPORT LEFT 2 114 FLAT WASHER 3 8 OD23 2t 12 115 HEX BOLT 3 8 3 4 12 116 HEX BOLT 3 8 1 8 117 FLAT WASHER 3 8 OD23 2...

Page 45: ...1 136 HEX BOLT 3 8 1 4 137 FLAT WASHER 3 8 OD23 2t 8 138 LOCK NUT 3 8 4 139 HEX BOLT 3 8 1 12 140 FLAT WASHER 3 8 OD23 2t 24 141 NUT 3 8 12 142 HEX BOLT 3 8 1 1 2 12 143 FLAT WASHER 3 8 OD23 2t 24 14...

Page 46: ...EX BOLT 3 8 3 4 4 162 FLAT WASHER 3 8 OD23 2t 4 163 CONNECTOR 1 164 HEX BOLT 3 8 1 16 165 FLAT WASHER 3 8 OD23 2t 32 166 LOCK NUT 3 8 16 167 PHILIP HD BOLT 3 16 3 8 4 168 HOSE CLAMP 1 1 4 4 169 FLEX H...

Page 47: ...10HP Stationary Dust Cyclone Manual 46 NOTES...

Page 48: ...ations subject to change Machines may be shown with optional accessories 2018 Laguna Tools Inc LAGUNA and the LAGUNA Logo are the registered trademarks of Laguna Tools Inc All rights reserved 2072 Alt...