background image

SKU 99925 

For technical questions, please call 1-800-444-3353. 

Page 5

rupter (GFCI) should also be imple-

mented – it prevents sustained elec-

trical shock.
Some dust created by power sand-

13. 

ing, sawing, grinding, drilling, and 

other construction activities, contains 

chemicals known [to the State of Cali-

fornia] to cause cancer, birth defects 

or other reproductive harm.  Some 

examples of these chemicals are: 

• Lead from lead-based paints

 

• Crystalline silica from bricks and ce

-

ment or other masonry products 

• Arsenic and chromium from chemi

-

cally treated lumber 

Your risk from these exposures var-

ies, depending on how often you do 

this type of work.  To reduce your 

exposure to these chemicals: work in 

a well ventilated area, and work with 

approved safety equipment, such as 

those dust masks that are specially 

designed to filter out microscopic 

particles.  (California Health & Safety 

Code § 25249.5, 

et seq.

)

WARNING: Handling the cord on 

14. 

this product will expose you to lead, 

a chemical known to the State of 

California to cause cancer, and birth 

defects or other reproductive harm. 

Wash hands after handling.  (Califor-

nia Health & Safety Code §  25249.5, 

et seq.)
The warnings, precautions, and in-

15. 

structions discussed in this instruction 

manual cannot cover all possible con-

ditions and situations that may occur.  

It must be understood by the operator 

that common sense and caution are 

factors which cannot be built into this 

product, but must be supplied by the 

operator. 

  saVe these 

instructions.

grounding

 

to preVent 

electric shocK 

and death From 

incorrect grounding 

Wire connection: 

Check with a qualified 

electrician if you are in doubt 

as to whether the outlet is 

properly grounded.  do not 

modify the power cord plug 

provided with the tool.  never 

remove the grounding prong 

from the plug.  do not use the 

tool if the power cord or plug 

is damaged.  if damaged, have 

it repaired by a service facility 

before use.  if the plug will not 

fit the outlet, have a proper 

outlet installed by a qualified 

electrician.

grounded tools: tools with three 

prong plugs

Tools marked with “Grounding Re-

1. 

quired” have a three wire cord and 

three prong grounding plug.  The 

plug must be connected to a properly 

grounded outlet.  If the tool should 

Summary of Contents for 99925

Page 1: ...nual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of...

Page 2: ...ndicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol...

Page 3: ...nsure the switch is in the off po sition before connecting to power source or moving the tool Do not overreach Keep proper d footing and balance at all times This enables better control of the tool in...

Page 4: ...attachment Risk of injury do not direct air 3 stream at body To reduce the risk of electric shock do not expose to rain Store indoors Do not use to supply breathing air 4 Do not direct air flow from t...

Page 5: ...nia to cause cancer and birth defects or other reproductive harm Wash hands after handling Califor nia Health Safety Code 25249 5 et seq The warnings precautions and in 15 structions discussed in this...

Page 6: ...green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to an electrically live terminal See 3 Prong Plug and Outlet The tool must be plugged...

Page 7: ...set up or use of this product To prevent serious injury from accidental operation Turn the Power Switch of the tool to its OFF position and unplug the tool from its electrical outlet before assemblin...

Page 8: ...hat will be used for 2 the job to the airline Close the in line safety valve be 3 tween the compressor and the tool Connect an air hose rated to the in 4 tended PSI that will be used with the tool to...

Page 9: ...ing the Air Compressor back in d will reset the circuit breaker turn Power Switch back to the ON e position and resume operation After the job is complete move the 11 Power Switch to the OFF position...

Page 10: ...condition that may affect its safe operation After Use 2 clean external surfaces of the tool with clean cloth 3 WARNING If the supply cord of this power tool is damaged it must be replaced only by a q...

Page 11: ...k air requirements of tools 3 Compressor operates but with low air output Valve or regulator loose or 1 leaking Valve or regulator damaged 2 Air tank not pressurized yet 3 Repair leaks 1 Have valve or...

Page 12: ...parts PARTS LIST Part Description Qty 1 Pad 2 2 Air Tank 1 3 Screw 4 4 Spacer 4 5 Washer 4 6 Bolt 4 7 Pump Motor Assembly 1 8 Oil Plug 1 9 Elbow 1 10 Shroud 1 11 Transfer Tube 1 12 Grip 1 13 Washer 2...

Page 13: ...SKU 99925 For technical questions please call 1 800 444 3353 Page 13 ASSEMBLY DIAGRAM...

Page 14: ...ecial or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limita tion of exclusion may...