background image

SKU 99925 

For technical questions, please call 1-800-444-3353. 

Page 4

maintain tools.  check for mis-

e. 

alignment or binding of moving 

parts, breakage of parts and any 

other condition that may affect the 

tool’s operation.  if damaged, have 

the tool repaired before use.

  Many 

accidents are caused by poorly main-

tained tools.

use the tool in accordance with 

f. 

these instructions, taking into ac-

count the working conditions and 

the work to be performed.  

Use of 

the tool for operations different from 

those intended could result in a haz

-

ardous situation.

service

5. 

have your tool serviced by a quali-

a. 

fied repair person using only iden

-

tical replacement parts.  

This will 

ensure that the safety of the tool is 

maintained.

air compressor safety Warnings

Risk of fire or explosion - do not 

1. 

spray flammable liquid in a confined 

area or towards a hot surface. Spray 

area must be well-ventilated. Do not 

smoke while spraying or spray where 

spark or flame is present. Arcing 

parts - keep compressor at least 20 

feet away from explosive vapors, 

such as when spraying with a spray 

gun.
Risk of bursting - do not adjust 

2. 

regulator to result in output pressure 

greater than marked maximum pres-

sure of attachment.
Risk of injury - do not direct air 

3. 

stream at body. To reduce the risk of 

electric shock, do not expose to rain. 

Store indoors.

Do not use to supply breathing air.

4. 

Do not direct air flow from the Com

-

5. 

pressor at people or animals.
Industrial applications must follow 

6. 

OSHA requirements.
Maintain labels and nameplates on 

7. 

the tool.  These carry important safety 

information.  If unreadable or miss-

ing, contact Harbor Freight Tools for a 

replacement.
Avoid unintentional starting.  Prepare 

8. 

to begin work before turning on the 

tool.
Do not leave the tool unattended 

9. 

when it is plugged into an electrical 

outlet.  Turn off the tool, and unplug it 

from its electrical outlet before leav-

ing.
This product is not a toy.  Keep it out 

10. 

of reach of children.
WARNING:  The brass components 

11. 

of this product contain lead, a chemi-

cal known to the State of California 

to cause birth defects (or other repro-

ductive harm). (California Health & 

Safety code § 25249.5, 

et seq.

)

People with pacemakers should 

12. 

consult their physician(s) before use.  

Electromagnetic fields in close prox

-

imity to heart pacemaker could cause 

pacemaker interference or pacemak-

er failure.  In addition, people with 

pacemakers should: 

• Avoid operating alone.

 

• Do not use with power switch locked 

on. 

• Properly maintain and inspect to 

avoid electrical shock. 

• Any power cord must be properly 

grounded.  Ground Fault Circuit Inter-

Summary of Contents for 99925

Page 1: ...nual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of...

Page 2: ...ndicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol...

Page 3: ...nsure the switch is in the off po sition before connecting to power source or moving the tool Do not overreach Keep proper d footing and balance at all times This enables better control of the tool in...

Page 4: ...attachment Risk of injury do not direct air 3 stream at body To reduce the risk of electric shock do not expose to rain Store indoors Do not use to supply breathing air 4 Do not direct air flow from t...

Page 5: ...nia to cause cancer and birth defects or other reproductive harm Wash hands after handling Califor nia Health Safety Code 25249 5 et seq The warnings precautions and in 15 structions discussed in this...

Page 6: ...green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to an electrically live terminal See 3 Prong Plug and Outlet The tool must be plugged...

Page 7: ...set up or use of this product To prevent serious injury from accidental operation Turn the Power Switch of the tool to its OFF position and unplug the tool from its electrical outlet before assemblin...

Page 8: ...hat will be used for 2 the job to the airline Close the in line safety valve be 3 tween the compressor and the tool Connect an air hose rated to the in 4 tended PSI that will be used with the tool to...

Page 9: ...ing the Air Compressor back in d will reset the circuit breaker turn Power Switch back to the ON e position and resume operation After the job is complete move the 11 Power Switch to the OFF position...

Page 10: ...condition that may affect its safe operation After Use 2 clean external surfaces of the tool with clean cloth 3 WARNING If the supply cord of this power tool is damaged it must be replaced only by a q...

Page 11: ...k air requirements of tools 3 Compressor operates but with low air output Valve or regulator loose or 1 leaking Valve or regulator damaged 2 Air tank not pressurized yet 3 Repair leaks 1 Have valve or...

Page 12: ...parts PARTS LIST Part Description Qty 1 Pad 2 2 Air Tank 1 3 Screw 4 4 Spacer 4 5 Washer 4 6 Bolt 4 7 Pump Motor Assembly 1 8 Oil Plug 1 9 Elbow 1 10 Shroud 1 11 Transfer Tube 1 12 Grip 1 13 Washer 2...

Page 13: ...SKU 99925 For technical questions please call 1 800 444 3353 Page 13 ASSEMBLY DIAGRAM...

Page 14: ...ecial or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limita tion of exclusion may...

Reviews: