Constant Injection System Electronic (CISE) - European Vehicles - FIGURE O:
gaUgE
(1)
PRESSURE TESTINg
aND
BLEED-OFF aSSY.
(25)
aDaPTERS
(10, 11, 12, 13, 15, 16, 18, 19, 20, 21, 22, 23, OR 24)
aND
“O-RINgS”
FIgURE O
1.
Turn off the ignition.
Clean the top of the fuel distributor to keep dirt from entering the fuel system.
2.
Relieve the fuel pressure. Refer to the vehicle’s service manual for specific pres
-
3.
sure relief procedures.
Connect the Gauge (1) to the Pressure Testing and Bleed-off Assembly (25).
4.
Install Adapter(s) (10, 11, 12, 13, 15, 16, 18, 19, 20, 21, 22, 23, or 24) and “O-
5.
Ring” to the engine as required.
Attach the female quick coupler on the Pressure Testing and Bleed-off Assembly
6.
(1) to the male quick coupler on the Adapter.
Start the engine and allow it to idle. Check for leaks. Read the fuel pressure.
7.
Compare the value on the Gauge (1) to the value in the service manual.
With free end of bleed-off hose in a suitable container, press button on side of
8.
bleed-off assembly slowly to release any air in the test Hose. Refer to the
Gen-
eral Safety Rules
section before removing tester from vehicle.
Remove tester and Adapter(s) from vehicle.
9.
Reconnect vehicle’s fuel injection lines to original condition.
10.
Start vehicle and check for leaks.