background image

Copyright © 20

20

 U-Line Corporation. All Rights Reserved. |  Publication Number 30379 |  

1

1

/20

20

 Rev. 

O

 

U-Line Corporation (U-Line) Limited Warranty

One Year Limited Warranty 

For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours.  

Two Year Limited Warranty (5 Class Product) 

For two years from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours. 

Available Second & Third Year Limited Warranty 

In addition to the standard one and two year warranties outlined above, U-Line offers a one year extension of the warranties from the date 
of purchase, free of charge. To take advantage of this extension, you must register your product with U-Line within 60 days from the date 
of purchase at u-line.com and provide proof of purchase. 

Five Year Sealed System Limited Warranty 

For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be 
defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line 
under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service 
provided during normal business hours. 

Terms 

These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten 
provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, 
maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and 
maintained in accordance with your product’s User Guide. 

The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any 
warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of 
these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal 
rights, and you may also have other rights which vary from state to state.   

Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of 

merchantability 

or any 

warranty 

fit for a particular purpose

 is limited to the duration of these warranties, and only extends to five years in duration for the parts 

described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty 
lasts, so the above limitations may not apply to you. 

The warranties only apply to the original purchaser and are non-transferable.

The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only.

The warranties apply to units operated outside only if designed for outdoor use by model and serial number.

U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and
third year limited warranties.

Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.

The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.

In-home instruction on how to use your product is not covered by these warranties.

Food, beverage, and medicine loss are not covered by these warranties.

If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip
charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.

Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only
and no coverage is provided for cosmetic defects.

Signal issues related to Wi-Fi connectivity are not covered by these warranties.

For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 

8900 N. 55

th

 

Street, Milwaukee, WI 53223 • u

-

line.com • onlineservice@u

-

line.com • +1.

414

.

354

.

0300

 

57

Summary of Contents for UCDE224ESS03A

Page 1: ...USER GUIDE SERVICE MANUAL Dispensers UCDE224 24 Mixed Use Dispenser...

Page 2: ...ation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Airflow and Product Loading Service Troubleshooting Wire Diagra...

Page 3: ...lect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty informat...

Page 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Page 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Page 6: ...or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are prese...

Page 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Page 8: ...ear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP SIDE 24 1 4 616 mm 23 1 8 587 mm 25 635 mm 4 102 mm 16 15 16 430 mm 4 102 mm 7 17...

Page 9: ...over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water l...

Page 10: ...allation 1 5 9 2 4 7 10 6 8 Safety and Warning Keep nitrogen tank in an upright position and handle with care Never exceed 60 PSI Ventilate area after nitrogen leak Required not included 1 Food grade...

Page 11: ...line up and press in firmly Note The connector at the end of the gas jumper line is narrower to correspond with the connection in the tower 2 Attach liquid jumper hose line up and press in firmly Not...

Page 12: ...SOURCE and connect to main source 6 Remove top cap from refrigerator and carefully slide refrigerator under countertop 7 Connect nitrogen and liquid lines to tower and feed lines through hole all the...

Page 13: ...stallation 12 1 2 TO FRONT OF REFRIGERATOR 11 13 16 TO SIDE OF REFRIGERATOR 1 4 HOLE 2 3 4 HOLE Template for Countertop Installation Note Verify template has printed true to scale double check hole di...

Page 14: ...ut and then use an adjustable wrench for an additional quarter turn DO NOT OVER TIGHTEN NOTE Make sure valve is in the off position turned clockwise as far as it can go 3 With a knife cut off one end...

Page 15: ...od grade lubricant to the inside of grommet 3 In the back of the unit remove back panel 4 Insert grommet into hole that corresponds to the drilled out hole in bulkhead and apply food grade lubricant t...

Page 16: ...isten for a click Pull up on the coupler to ensure it is locked down Other end is connected to T connector on Infuser Regulator 1 2 7 Attach and clamp blue hose to lo boy coupling Connecting Internal...

Page 17: ...cabinet drill out 1 of the holes in the bulk head 2 Insert insulation such as a grommet into drilled out hole It may be necessary to apply food grade lubricant to the inside of the grommet 3 In the ba...

Page 18: ...op of the coupler while pulling up on the collar Press coupler down firmly onto out valve Release collar listen for a click Pull up on the coupler to ensure it is locked down 2 Connect and clamp clear...

Page 19: ...applicable federal state and local codes it may be necessary to caulk the refrigerator to the floor CASTERS optional 1 Remove grille and back panel to access nuts 2 Remove each nut and unscrew each l...

Page 20: ...e installed Removing the grille Note Grille and display are attached The length of the display wire is sufficient to allow access to the front base components 1 Disconnect power to the unit 2 Loosen t...

Page 21: ...ng Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wa...

Page 22: ...ove top and bottom hinge screws using a Philips screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the wa...

Page 23: ...posite side of cabinet On some models there may be a nut behind one or both screws on either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Install top h...

Page 24: ...ed temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit to reach set points before loading To d...

Page 25: ...s reached and retighten locking nut 5 On infuser regulator pull out middle knob to unlock then turn knob until needle points at 7 turn right to increase left to decrease 6 Once set lock in place by pr...

Page 26: ...all The secondary regulator is set to a pressure that is either too high or low If there is less more nitro effect than desired use the black knob on the secondary regulator assembly to make a change...

Page 27: ...IDE FUNCTION COMMAND NOTES ON OFF Press and hold for 5 seconds Unit will turn On or OFF Adjust Temperature Press or and release When the display is flashing press or to adjust the set point temperatur...

Page 28: ...ratures and may freeze contents Do not block the front grille no additional clearance around sides top or rear of unit is needed for ventilation Do not install behind a closed door When loading leave...

Page 29: ...ned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible CLEAN INTERIOR COMPONENTS Use warm or hot water with dish soap to clean all remove...

Page 30: ...the tap heads with warm soapy water Remove nose cones and soak in the cleaning solution for at least five minutes Rinse with clean potable water dry and reattach Infuser Filter Disassemble by unscrew...

Page 31: ...er 5 Open tap coupler to allow cleaning solution to flow through it Push base of coupler inward and rotate clockwise 6 Open cleaning pump 7 Empty one packet of cleaner into plastic jar and fill with c...

Page 32: ...tap head wrench 11 Pump all the solution through the beverage line 13 Rinse out and refill plastic jar with clean water Pump all the water through the beverage line to rinse 14 Rinse all disassembled...

Page 33: ...inner lining or damage the cooling unit DO NOT use any type of heater to defrost Using a heater to speed up defrosting can cause personal injury and damage to the inner lining NOTICE The drain pan wa...

Page 34: ...nvironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condens...

Page 35: ...unit allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 Clean the system See CLEANING 6 The door must remain open to prevent format...

Page 36: ...ompressor makes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the un...

Page 37: ...ng the testing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal tempera...

Page 38: ...e White Black N C 1 6 Evap Cond fan Light Evap temp Zone temp Door switch Compressor FUSE Programming U s e r I n t e r f a c e 42376_C If Applicable POWER CORD ASSEMBLY 220 240 VOLT PLUG LIVE BLACK 1...

Page 39: ...zed to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from t...

Page 40: ...ing for warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update...

Page 41: ...R FAN W SCREWS 80 54014 00 8 CONTROL ASSEMBLY 80 55552 01 9 DOOR ASSY 24 SOLID STAINLESS 80 55421 01 10 DRAIN TROUGH 5 CLASS 24 80 55484 00 11 DRIER 80 54055 00 12 EVAP ASSY 5 CLASS 24 80 55486 00 14...

Page 42: ...ms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will...

Page 43: ...cian must observe all federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder t...

Page 44: ...cuum pump and recovery equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the sys...

Page 45: ...erant is left within the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing...

Page 46: ...Install a Schrader Type access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two...

Page 47: ...erature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes war...

Page 48: ...h are not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefu...

Page 49: ...2547 for assistance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Des...

Page 50: ...Mode OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Thermistor failure OHM thermistor...

Page 51: ...e Plunger Switch Replace Main Board Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Plunger Switch Operating Properly Inspect Customer UI and Data Cable Connect Test Display Cyc...

Page 52: ...LED activated with button activation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES Defrost Duration Enter menu by pressing for more than 5 seconds Use or to increase reduce defrost duration Press to...

Page 53: ...E Zone Thermistor If the zone thermistor in the unit fails the unit will continue to cool in a backup mode Self Preservation Mode to preserve the integrity of the contents The unit will otherwise oper...

Page 54: ...or units defrost every 12 hours of compressor runtime for 45 minutes If you have verified that the unit does not have an ambient air leak utilize the Control Operation Service section and adjust unit...

Page 55: ...ondensation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door switch In order to operate effi...

Page 56: ...ator cover vents and push air out at fan mounting location 15 Installation is the reverse of removal 16 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front...

Page 57: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Reviews: