USER GUIDE
u-line.com
General Installation
Connecting External Nitrogen
Source
Note: Connection to an external Nitrogen source
requires drilling one hole through the pre-
installed bulkhead located near the top of the
back wall. This will allow a grommet sized to
.453" hose to fit.
Install Infuser Regulator
1. Align infuser regulator with pre-drilled holes in upper
back corner of desired side wall. Use 2 screws to attach
regulator.
Prepare bulkhead and back panel
1. Inside the cabinet, drill out 1 of the
⁹/16
" holes in the
bulkhead.
2. Insert grommet into drilled-out hole and apply food
grade lubricant to the inside of grommet.
3. In the back of the unit, remove back panel.
4. Insert grommet into hole that corresponds to the
drilled-out hole in bulkhead and apply food grade
lubricant to inside of the grommet.
5. Inside cabinet push nitrogen hose through drilled-out
hole.
6. At the back of the unit, apply food grade lubricant
to inside of the grommet and push nitrogen hose
through.
7. Re-install back panel.
8. Connect nitrogen hose to external nitrogen source.
9. Continue with inside connections (see CONNECT
NITROGEN TO KEGS in this manual)
Interior Left
Side Wall
To Tap Tower
Bac
k W
all
Bulk
hea
d
psi
0
2
4
6
8 1
0
12
14
Nitrogen IN
From Source
Nitrogen OUT
To Ball-tap Keg
Nitrogen OUT
To Slim Keg and Tower
BULKHEAD
Connects to
external Nitrogen
Outside
Inside
15