background image

11/2006

9

www.U-LineService.com

CO1175 — Ice Maker/Refrigerator

Checking Door Alignment

The unit’s door is aligned at the factory before shipment. 
However, its alignment could have been disturbed during 
shipment or during door panel installation.

IMPORTANT

Properly aligned, the door's gasket should be firmly in 
contact with the cabinet all the way around the door (no 
gaps).

1. Carefully examine the door's gasket to assure that it is 

firmly in contact with the cabinet.

Note: 

When inspecting door alignment, make sure the 

light switch bracket makes contact with the light switch 
plunger. Also make sure the door gasket is not pinched on 
the hinge side of the door

.

2. If the door is properly aligned, go on to 

6 Prepare 

Plumbing

. If it is not, use the following procedure.

Adjusting Door Alignment

1. Loosen (do not remove) 

top and bottom hinge 
screws. See 

Figure 15

.

2. Align door squarely with 

cabinet. Make sure gasket 
is firmly in contact with 
cabinet all the way around 
the door (no gaps).

3. Tighten bottom hinge 

screws.

4. Tighten top hinge screws. 

Go on to 

6 Prepare 

Plumbing

.

CAUTION

Plumbing installation must observe all state and local 
codes. All water connections MUST BE made by a licensed/
qualified plumbing contractor. Failure to follow 
recommendations and instructions may result in damage 
and/or harm.

WARNING

To prevent accidental electrocution, make certain 
that the floor surfaces surrounding the unit are 
dry whenever power is removed from, or applied 
to, the unit.

Water Supply Connection

When connecting the water supply, follow these 
guidelines:

• Review the local plumbing codes before you install the 

unit.

• Connect to the cold water supply.
• The water pressure should be between 20 and 120 psi.
• Install a shutoff valve in the 1/4 inch OD water supply 

line.

• Connect sufficient tubing to the unit so that tubing 

may be looped, allowing the unit to be removed for 
cleaning and servicing (see 

Figure 18

). However, make 

certain that the tubing is not pinched or damaged 
during installation.

• U-Line recommends the use of copper tubing for 

installation.

To connect to water supply:

1. Install the 1/4 inch OD copper water line from the 

main water source.

5 Adjust Door

Figure 15

6 Prepare Plumbing

Summary of Contents for Origins CO1175AS

Page 1: ...rvice com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2006 U Line Corporation 11 2006 CO1175 Ice Maker Refrigerator Instal...

Page 2: ...is unit requires connection to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a li...

Page 3: ...ion parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in a safe place for f...

Page 4: ...olors or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a non abrasive cloth Always clean in the direction of the grain Always finish this process with Claire Stainles...

Page 5: ...next to a wall or similar type of structure All left hand hinged units require a minimum of 1 4 door clearance if installed flush with cabinet or wall and 8 clearance for Black Stainless Steel units i...

Page 6: ...rt screw and reinstall pivot screw in hinge See Figure 6 7 Install bottom hinge on cabinet opposite side aligning flat edge of hinge with outer edge of unit Partially tighten screws See Figure 8 8 Rel...

Page 7: ...ries units side by side CO1175 1175R Refrigerator or 1175WC Wine Captain Note that each Side By Side Installation will be different Cut out width for a side by side installation is the total of the wi...

Page 8: ...Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head screwdriver Remove door by tilting forward and lifting off bottom hinge pin 2 Pull door g...

Page 9: ...ttom hinge screws 4 Tighten top hinge screws Go on to 6 Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes All water connections MUST BE made by a licensed qualified...

Page 10: ...5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized re...

Page 11: ...e unit after it is correctly positioned in the opening Installation of the CO75A 1 Open the water supply valve in the main water source 2 Plug in the power cord 3 Gently push the unit into position Be...

Page 12: ...n 4 and 5 Assure that setting was not altered in shipment No other adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon as t...

Page 13: ...Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more Problem Q The cubes produced during the first two to three...

Reviews: